Change history for item: Termet Windsor plus 30 Double circuit

  1. Donny Darko 08 July 2023 06:34:39
    1. Create: Description #3417223
      Value: Type of heating boiler: gas, max. heating power: 28.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3417224
      Value: Gas, condensing
    3. Create: Burner #3417225
      Value: Gas
    4. Create: Number of circuits #3417226
      Value: Double-circuit
    5. Create: Thermal power #3417227
      Value: 6.70 - 28.80 kW
    6. Create: Thermal load #3417228
      Value: 7.50 - 31.10 kW
    7. Create: The combustion chamber #3417229
      Value: Closed
    8. Create: Efficiency #3417230
      Value: 107.5 %
    9. Create: Control #3417231
      Value: Electronic
    10. Create: Installation #3417232
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3417233
      Value: Stainless steel
    12. Create: Mains voltage #3417234
      Value: Single-phase
    13. Create: Peculiarities #3417235
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3417236
      Value: 8 l
    15. Create: Equipment #3417237
      Value: Display
    16. Create: Fuel #3417238
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3417239
      Value: 3.1 cu. m/hour
    18. Create: LPG consumption #3417240
      Value: 2.3 kg/hour
    19. Create: Nominal pressure of natural gas #3417241
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3417242
      Value: 37 mbar
    21. Create: Heat carrier temperature #3417243
      Value: 20 - 95 °С
    22. Create: Temperature in the DHW circuit #3417244
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 30°C #3417245
      Value: 13.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3417246
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3417247
      Value: 3 bar
    26. Create: Gas connection #3417248
      Value: 3/4"
    27. Create: Heating circuit connection #3417249
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3417250
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3417251
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3417252
      Value: Yes
    31. Create: Dimensions WxHxD #3417253
      Value: 400x705x420mm
    32. Create: Weight #3417254
      Value: 42 kg
    33. Create: Image #6323667
      URL: https://avatars.mds.yandex.net/get-mpic/4304254/img_id8348067463183689713.jpeg/orig
    34. Create: Preview image #6323668
      URL: https://avatars.mds.yandex.net/get-mpic/4304254/img_id8348067463183689713.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:40
    Name: Termet Windsor plus 30 Double circuit; Catalog: Heating boilers