Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:34:30
Create:
Description #3417125
Value: Type of heating boiler: gas, max. thermal power: 29 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3417126
Value: Gas, convection
Create:
Burner #3417127
Value: Gas
Create:
Number of circuits #3417128
Value: Double-circuit
Create:
Thermal power #3417129
Value: 8 - 29 kW
Create:
Thermal load #3417130
Value: 9.20 - 31.50 kW
Create:
The combustion chamber #3417131
Value: Closed
Create:
Efficiency #3417132
Value: 92 %
Create:
Control #3417133
Value: Electronic
Create:
Installation #3417134
Value: Wall-mounted
Create:
Primary heat exchanger material #3417135
Value: Copper
Create:
Secondary heat exchanger material #3417136
Value: Stainless steel
Create:
Mains voltage #3417137
Value: Single-phase
Create:
Peculiarities #3417138
Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3417139
Value: 6 l
Create:
Equipment #3417140
Value: Display
Create:
Fuel #3417141
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3417142
Value: 3.3 cu. m/hour
Create:
LPG consumption #3417143
Value: 2.4 kg/hour
Create:
Nominal pressure of natural gas #3417144
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3417145
Value: 37 mbar
Create:
Heat carrier temperature #3417146
Value: 35 - 85 °С
Create:
Temperature in the DHW circuit #3417147
Value: 30 - 60 °С
Create:
Hot water capacity at t 30°C #3417148
Value: 13.8 l/min
Create:
Max. water pressure in the DHW circuit #3417149
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3417150
Value: 3 bar
Create:
Gas connection #3417151
Value: 3/4"
Create:
Heating circuit connection #3417152
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3417153
Value: 1/2"
Create:
Coaxial chimney diameter #3417154
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3417155
Value: Yes
Create:
Dimensions WxHxD #3417156
Value: 360x700x300 mm
Create:
Weight #3417157
Value: 31 kg
Create:
Image #6323661
URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id6612605518613349782.jpeg/orig
Create:
Preview image #6323662
URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id6612605518613349782.jpeg/orig
Donny Darko 30 April 2023 08:27:39
Name: Termet MiniMax 29 FF ELEGANCE 29 kW double circuit; Catalog: Heating boilers