Change history for item: Termet MaxiTerm 33 CF ELEGANCE 33 kW dual circuit

  1. Donny Darko 08 July 2023 06:34:23
    1. Create: Description #3417063
      Value: Type of heating boiler: gas, max. thermal power: 33 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3417064
      Value: Gas, convection
    3. Create: Burner #3417065
      Value: Gas
    4. Create: Number of circuits #3417066
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3417067
      Value: 10 - 33 kW
    6. Create: Thermal load #3417068
      Value: 11.10 - 35.90 kW
    7. Create: The combustion chamber #3417069
      Value: Open
    8. Create: Efficiency #3417070
      Value: 91.5 %
    9. Create: Control #3417071
      Value: Electronic
    10. Create: Installation #3417072
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3417073
      Value: Copper
    12. Create: Mains voltage #3417074
      Value: Single-phase
    13. Create: Peculiarities #3417075
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3417076
      Value: 6 l
    15. Create: Equipment #3417077
      Value: Display
    16. Create: Fuel #3417078
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3417079
      Value: 3.7 cu. m/hour
    18. Create: LPG consumption #3417080
      Value: 2.7 kg/hour
    19. Create: Nominal pressure of natural gas #3417081
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3417082
      Value: 37 mbar
    21. Create: Heat carrier temperature #3417083
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3417084
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 30°C #3417085
      Value: 15.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3417086
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3417087
      Value: 3 bar
    26. Create: Gas connection #3417088
      Value: 3/4"
    27. Create: Heating circuit connection #3417089
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3417090
      Value: 1/2"
    29. Create: Chimney diameter #3417091
      Value: 130 mm
    30. Create: Dimensions WxHxD #3417092
      Value: 485x750x330 mm
    31. Create: Weight #3417093
      Value: 37 kg
    32. Create: Image #6323657
      URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id7328334589490312769.jpeg/orig
    33. Create: Preview image #6323658
      URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id7328334589490312769.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:39
    Name: Termet MaxiTerm 33 CF ELEGANCE 33 kW dual circuit; Catalog: Heating boilers