Change history for item: Termet MaxiTerm 29 CF ELEGANCE 29 kW dual circuit

  1. Donny Darko 08 July 2023 06:34:20
    1. Create: Description #3417032
      Value: Type of heating boiler: gas, max. thermal power: 29 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3417033
      Value: Gas, convection
    3. Create: Burner #3417034
      Value: Gas
    4. Create: Number of circuits #3417035
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3417036
      Value: 10 - 29 kW
    6. Create: Thermal load #3417037
      Value: 11.10 - 31.70 kW
    7. Create: The combustion chamber #3417038
      Value: Open
    8. Create: Efficiency #3417039
      Value: 91.5 %
    9. Create: Control #3417040
      Value: Electronic
    10. Create: Installation #3417041
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3417042
      Value: Copper
    12. Create: Mains voltage #3417043
      Value: Single-phase
    13. Create: Peculiarities #3417044
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3417045
      Value: 6 l
    15. Create: Equipment #3417046
      Value: Display
    16. Create: Fuel #3417047
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3417048
      Value: 3.3 cu. m/hour
    18. Create: LPG consumption #3417049
      Value: 2.4 kg/hour
    19. Create: Nominal pressure of natural gas #3417050
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3417051
      Value: 37 mbar
    21. Create: Heat carrier temperature #3417052
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3417053
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 30°C #3417054
      Value: 13.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3417055
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3417056
      Value: 3 bar
    26. Create: Gas connection #3417057
      Value: 3/4"
    27. Create: Heating circuit connection #3417058
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3417059
      Value: 1/2"
    29. Create: Chimney diameter #3417060
      Value: 130 mm
    30. Create: Dimensions WxHxD #3417061
      Value: 485x750x330 mm
    31. Create: Weight #3417062
      Value: 32 kg
    32. Create: Image #6323655
      URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id7492584304442087232.jpeg/orig
    33. Create: Preview image #6323656
      URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id7492584304442087232.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:39
    Name: Termet MaxiTerm 29 CF ELEGANCE 29 kW dual circuit; Catalog: Heating boilers