Change history for item: Termet MiniTerm 24 FF ELEGANCE 24 kW dual circuit

  1. Donny Darko 08 July 2023 06:34:17
    1. Create: Description #3417000
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3417001
      Value: Gas, convection
    3. Create: Burner #3417002
      Value: Gas
    4. Create: Number of circuits #3417003
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3417004
      Value: 7 - 24 kW
    6. Create: Thermal load #3417005
      Value: 7.90 - 26 kW
    7. Create: The combustion chamber #3417006
      Value: Closed
    8. Create: Efficiency #3417007
      Value: 92 %
    9. Create: Control #3417008
      Value: Electronic
    10. Create: Installation #3417009
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3417010
      Value: Copper
    12. Create: Mains voltage #3417011
      Value: Single-phase
    13. Create: Peculiarities #3417012
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3417013
      Value: 6 l
    15. Create: Equipment #3417014
      Value: Display
    16. Create: Fuel #3417015
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3417016
      Value: 2.8 cu. m/hour
    18. Create: LPG consumption #3417017
      Value: 2 kg/hour
    19. Create: Nominal pressure of natural gas #3417018
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3417019
      Value: 37 mbar
    21. Create: Heat carrier temperature #3417020
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3417021
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 30°C #3417022
      Value: 11.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3417023
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3417024
      Value: 3 bar
    26. Create: Gas connection #3417025
      Value: 3/4"
    27. Create: Heating circuit connection #3417026
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3417027
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3417028
      Value: 60/100 mm and 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3417029
      Value: Yes
    31. Create: Dimensions WxHxD #3417030
      Value: 360x700x300 mm
    32. Create: Weight #3417031
      Value: 305 kg
    33. Create: Image #6323653
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id2907909720935218150.jpeg/orig
    34. Create: Preview image #6323654
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id2907909720935218150.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:38
    Name: Termet MiniTerm 24 FF ELEGANCE 24 kW dual circuit; Catalog: Heating boilers