Change history for item: Termet MaxiTerm 33 33 kW dual circuit

  1. Donny Darko 08 July 2023 06:33:03
    1. Create: Description #3416370
      Value: Type of heating boiler: gas, max. thermal power: 33 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3416371
      Value: Gas, convection
    3. Create: Burner #3416372
      Value: Gas
    4. Create: Number of circuits #3416373
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3416374
      Value: 10 - 33 kW
    6. Create: Thermal load #3416375
      Value: 11.10 - 35.90 kW
    7. Create: The combustion chamber #3416376
      Value: Open
    8. Create: Efficiency #3416377
      Value: 91.5 %
    9. Create: Control #3416378
      Value: Electronic
    10. Create: Installation #3416379
      Value: Wall-mounted
    11. Create: Mains voltage #3416380
      Value: Single-phase
    12. Create: Peculiarities #3416381
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Equipment #3416382
      Value: Display
    14. Create: Fuel #3416383
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3416384
      Value: 3.7 cu. m/hour
    16. Create: LPG consumption #3416385
      Value: 2.7 kg/hour
    17. Create: Nominal pressure of natural gas #3416386
      Value: 13 - 20 mbar
    18. Create: Permissible LPG pressure #3416387
      Value: 37 mbar
    19. Create: Heat carrier temperature #3416388
      Value: 40 - 95 °С
    20. Create: Temperature in the DHW circuit #3416389
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 30°C #3416390
      Value: 15.8 l/min
    22. Create: Max. water pressure in the DHW circuit #3416391
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3416392
      Value: 3 bar
    24. Create: Gas connection #3416393
      Value: 3/4"
    25. Create: Heating circuit connection #3416394
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3416395
      Value: 1/2"
    27. Create: Dimensions WxHxD #3416396
      Value: 460x700x300 mm
    28. Create: Weight #3416397
      Value: 37 kg
    29. Create: Image #6323605
      URL: https://avatars.mds.yandex.net/get-mpic/3749045/img_id26022867958752531.jpeg/orig
    30. Create: Preview image #6323606
      URL: https://avatars.mds.yandex.net/get-mpic/3749045/img_id26022867958752531.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:31
    Name: Termet MaxiTerm 33 33 kW dual circuit; Catalog: Heating boilers