Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:33:00
Create:
Description #3416337
Value: Type of heating boiler: gas, max. thermal power: 29 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3416338
Value: Gas, convection
Create:
Burner #3416339
Value: Gas
Create:
Number of circuits #3416340
Value: Double-circuit
Create:
Thermal power #3416341
Value: 8 - 29 kW
Create:
Thermal load #3416342
Value: 9.20 - 31.50 kW
Create:
The combustion chamber #3416343
Value: Closed
Create:
Efficiency #3416344
Value: 92 %
Create:
Control #3416345
Value: Electronic
Create:
Installation #3416346
Value: Wall-mounted
Create:
Primary heat exchanger material #3416347
Value: Copper
Create:
Secondary heat exchanger material #3416348
Value: Stainless steel
Create:
Mains voltage #3416349
Value: Single-phase
Create:
Peculiarities #3416350
Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3416351
Value: 6 l
Create:
Equipment #3416352
Value: Display
Create:
Fuel #3416353
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3416354
Value: 3.3 cu. m/hour
Create:
LPG consumption #3416355
Value: 2.7 kg/hour
Create:
Nominal pressure of natural gas #3416356
Value: 20 mbar
Create:
Permissible LPG pressure #3416357
Value: 37 mbar
Create:
Heat carrier temperature #3416358
Value: 40 - 95 °С
Create:
Temperature in the DHW circuit #3416359
Value: 30 - 60 °С
Create:
Hot water capacity at t 30°C #3416360
Value: 13.8 l/min
Create:
Max. water pressure in the DHW circuit #3416361
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3416362
Value: 3 bar
Create:
Gas connection #3416363
Value: 3/4"
Create:
Heating circuit connection #3416364
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3416365
Value: 1/2"
Create:
Coaxial chimney diameter #3416366
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3416367
Value: Yes
Create:
Dimensions WxHxD #3416368
Value: 360x700x300 mm
Create:
Weight #3416369
Value: 33 kg
Create:
Image #6323603
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id4965738542818900822/orig
Create:
Preview image #6323604
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id4965738542818900822/orig
Donny Darko 30 April 2023 08:27:31
Name: Termet MiniMax dynamic turbo 29 29 kW dual circuit; Catalog: Heating boilers