Change history for item: Termet MiniMax dynamic 24 24 kW dual circuit

  1. Donny Darko 08 July 2023 06:32:53
    1. Create: Description #3416272
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3416273
      Value: Gas, convection
    3. Create: Burner #3416274
      Value: Gas
    4. Create: Number of circuits #3416275
      Value: Double-circuit
    5. Create: Thermal power #3416276
      Value: 7 - 24 kW
    6. Create: Thermal load #3416277
      Value: 7.90 - 26.40 kW
    7. Create: The combustion chamber #3416278
      Value: Open
    8. Create: Efficiency #3416279
      Value: 91 %
    9. Create: Control #3416280
      Value: Electronic
    10. Create: Installation #3416281
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3416282
      Value: Copper
    12. Create: Secondary heat exchanger material #3416283
      Value: Stainless steel
    13. Create: Mains voltage #3416284
      Value: Single-phase
    14. Create: Peculiarities #3416285
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3416286
      Value: 6 l
    16. Create: Equipment #3416287
      Value: Display
    17. Create: Fuel #3416288
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3416289
      Value: 2.7 cu. m/hour
    19. Create: LPG consumption #3416290
      Value: 2 kg/hour
    20. Create: Nominal pressure of natural gas #3416291
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3416292
      Value: 37 mbar
    22. Create: Heat carrier temperature #3416293
      Value: 40 - 85 °С
    23. Create: Temperature in the DHW circuit #3416294
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 30°C #3416295
      Value: 11.4 l/min
    25. Create: Max. water pressure in the DHW circuit #3416296
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3416297
      Value: 3 bar
    27. Create: Gas connection #3416298
      Value: 3/4"
    28. Create: Heating circuit connection #3416299
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3416300
      Value: 1/2"
    30. Create: Chimney diameter #3416301
      Value: 130 mm
    31. Create: Dimensions WxHxD #3416302
      Value: 360x700x300 mm
    32. Create: Weight #3416303
      Value: 28 kg
    33. Create: Image #6323599
      URL: https://avatars.mds.yandex.net/get-mpic/1860966/img_id4044138518818960976/orig
    34. Create: Preview image #6323600
      URL: https://avatars.mds.yandex.net/get-mpic/1860966/img_id4044138518818960976/orig
  2. Donny Darko 30 April 2023 08:27:31
    Name: Termet MiniMax dynamic 24 24 kW dual circuit; Catalog: Heating boilers