Change history for item: Termet MaxiTerm 29 29 kW dual circuit

  1. Donny Darko 08 July 2023 06:32:49
    1. Create: Description #3416244
      Value: Type of heating boiler: gas, max. thermal power: 29 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3416245
      Value: Gas, convection
    3. Create: Burner #3416246
      Value: Gas
    4. Create: Number of circuits #3416247
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3416248
      Value: 10 - 29 kW
    6. Create: Thermal load #3416249
      Value: 11.10 - 31.50 kW
    7. Create: The combustion chamber #3416250
      Value: Open
    8. Create: Efficiency #3416251
      Value: 91.5 %
    9. Create: Control #3416252
      Value: Electronic
    10. Create: Installation #3416253
      Value: Wall-mounted
    11. Create: Mains voltage #3416254
      Value: Single-phase
    12. Create: Peculiarities #3416255
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Equipment #3416256
      Value: Display
    14. Create: Fuel #3416257
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3416258
      Value: 3.3 cu. m/hour
    16. Create: LPG consumption #3416259
      Value: 2.4 kg/hour
    17. Create: Nominal pressure of natural gas #3416260
      Value: 13 - 20 mbar
    18. Create: Permissible LPG pressure #3416261
      Value: 37 mbar
    19. Create: Heat carrier temperature #3416262
      Value: 40 - 95 °С
    20. Create: Temperature in the DHW circuit #3416263
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 30°C #3416264
      Value: 13.8 l/min
    22. Create: Max. water pressure in the DHW circuit #3416265
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3416266
      Value: 3 bar
    24. Create: Gas connection #3416267
      Value: 3/4"
    25. Create: Heating circuit connection #3416268
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3416269
      Value: 1/2"
    27. Create: Dimensions WxHxD #3416270
      Value: 460x700x300 mm
    28. Create: Weight #3416271
      Value: 35 kg
    29. Create: Image #6323597
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id2159536338262188661.jpeg/orig
    30. Create: Preview image #6323598
      URL: https://avatars.mds.yandex.net/get-mpic/3732535/img_id2159536338262188661.jpeg/orig
  2. Donny Darko 30 April 2023 08:27:30