Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:27:16
Create:
Description #3415611
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3415612
Value: Gas, convection
Create:
Burner #3415613
Value: Gas
Create:
Number of circuits #3415614
Value: Double-circuit
Create:
Thermal power #3415615
Value: 9.50 - 24 kW
Create:
Thermal load #3415616
Value: 11 - 28.70 kW
Create:
The combustion chamber #3415617
Value: Closed
Create:
Heated area #3415618
Value: 240 sq.m
Create:
Efficiency #3415619
Value: 93.7 %
Create:
Control #3415620
Value: Electronic
Create:
Installation #3415621
Value: Wall-mounted
Create:
Primary heat exchanger material #3415622
Value: Copper
Create:
Mains voltage #3415623
Value: Single-phase
Create:
Peculiarities #3415624
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3415625
Value: 8 l
Create:
Equipment #3415626
Value: Display
Create:
Fuel #3415627
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3415628
Value: 2.73 cu. m/hour
Create:
LPG consumption #3415629
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3415630
Value: 20 mbar
Create:
Permissible LPG pressure #3415631
Value: 37 mbar
Create:
Heat carrier temperature #3415632
Value: 35 - 82 °С
Create:
Temperature in the DHW circuit #3415633
Value: 36 - 60 °С
Create:
Hot water capacity at t 25°C #3415634
Value: 13.5 l/min
Create:
Hot water capacity at t 35°C #3415635
Value: 9.6 l/min
Create:
Max. water pressure in the DHW circuit #3415636
Value: 7 bar
Create:
Max. water pressure in the heating circuit #3415637
Value: 3 bar
Create:
Gas connection #3415638
Value: 3/4"
Create:
Heating circuit connection #3415639
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3415640
Value: 1/2"
Create:
Coaxial chimney diameter #3415641
Value: 60/100 mm
Create:
Dimensions WxHxD #3415642
Value: 400x745x319 mm
Create:
Weight #3415643
Value: 31 kg
Create:
Image #6323479
URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id5637144931422743515.jpeg/orig
Create:
Image #6323480
URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id438977712466603393.jpeg/orig
Create:
Image #6323481
URL: https://avatars.mds.yandex.net/get-mpic/7937668/img_id7955930393137677069.jpeg/orig
Create:
Image #6323482
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id495263224308227097.jpeg/orig
Create:
Image #6323483
URL: https://avatars.mds.yandex.net/get-mpic/4559636/img_id4660042633448673268.jpeg/orig
Create:
Preview image #6323484
URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id5637144931422743515.jpeg/orig
Donny Darko 30 April 2023 08:27:04
Name: Boiler ARISTON ALTEAS XC 24 FF NG; Catalog: Heating boilers