Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:26:38
Create:
Description #3415439
Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3415440
Value: Gas, convection
Create:
Burner #3415441
Value: Gas
Create:
Number of circuits #3415442
Value: Double-circuit
Create:
Thermal power #3415443
Value: 13 - 30 kW
Create:
Thermal load #3415444
Value: 14.40 - 33.30 kW
Create:
The combustion chamber #3415445
Value: Closed
Create:
Heated area #3415446
Value: 300 sq.m
Create:
Efficiency #3415447
Value: 93.8 %
Create:
Control #3415448
Value: Electronic
Create:
Installation #3415449
Value: Wall-mounted
Create:
Primary heat exchanger material #3415450
Value: Copper
Create:
Mains voltage #3415451
Value: Single-phase
Create:
Peculiarities #3415452
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3415453
Value: 8 l
Create:
Equipment #3415454
Value: Display
Create:
Fuel #3415455
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3415456
Value: 3.17 cu. m/hour
Create:
LPG consumption #3415457
Value: 2.33 kg/hour
Create:
Nominal pressure of natural gas #3415458
Value: 20 mbar
Create:
Permissible LPG pressure #3415459
Value: 37 mbar
Create:
Heat carrier temperature #3415460
Value: 35 - 82 °С
Create:
Temperature in the DHW circuit #3415461
Value: 36 - 60 °С
Create:
Hot water capacity at t 25°C #3415462
Value: 15.7 l/min
Create:
Hot water capacity at t 35°C #3415463
Value: 11.2 l/min
Create:
Max. water pressure in the DHW circuit #3415464
Value: 7 bar
Create:
Max. water pressure in the heating circuit #3415465
Value: 3 bar
Create:
Gas connection #3415466
Value: 3/4"
Create:
Heating circuit connection #3415467
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3415468
Value: 1/2"
Create:
Coaxial chimney diameter #3415469
Value: 60/100 mm
Create:
Dimensions WxHxD #3415470
Value: 400x745x319 mm
Create:
Weight #3415471
Value: 32 kg
Create:
Image #6323444
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id5097027088797497415.jpeg/orig
Create:
Image #6323445
URL: https://avatars.mds.yandex.net/get-mpic/1571231/img_id7163402875803693282.jpeg/orig
Create:
Image #6323446
URL: https://avatars.mds.yandex.net/get-mpic/4055817/img_id919591502749350944.jpeg/orig
Create:
Preview image #6323447
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id5097027088797497415.jpeg/orig
Donny Darko 30 April 2023 08:27:02
Name: Traditional boiler ARISTON ALTEAS XC 30 FF NG; Catalog: Heating boilers