      Value: Type of heating boiler: gas, max. thermal power: 15 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3414860
      Value: Gas, convection
    3. Create: Burner #3414861
      Value: Gas
    4. Create: Number of circuits #3414862
      Value: Double-circuit
    5. Create: Thermal power #3414863
      Value: 11 - 15 kW
    6. Create: The combustion chamber #3414864
      Value: Closed
    7. Create: Efficiency #3414865
      Value: 92.9 %
    8. Create: Control #3414866
      Value: Electronic
    9. Create: Installation #3414867
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3414868
      Value: Aluminum
    11. Create: Secondary heat exchanger material #3414869
      Value: Copper
    12. Create: Mains voltage #3414870
      Value: Single-phase
    13. Create: Peculiarities #3414871
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3414872
      Value: 8 l
    15. Create: Equipment #3414873
      Value: Built-in exhaust fan, built-in blower, display
    16. Create: Fuel #3414874
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3414875
      Value: 2.73 cu. m/hour
    18. Create: LPG consumption #3414876
      Value: 2 kg/hour
    19. Create: Nominal pressure of natural gas #3414877
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3414878
      Value: 37 mbar
    21. Create: Heat carrier temperature #3414879
      Value: 35 - 82 °С
    22. Create: Temperature in the DHW circuit #3414880
      Value: 36 - 60 °С
    23. Create: Hot water capacity at t 25°C #3414881
      Value: 13.5 l/min
    24. Create: Hot water capacity at t 30°C #3414882
      Value: 11.2 l/min
    25. Create: Hot water capacity at t 35°C #3414883
      Value: 9.6 l/min
    26. Create: Max. water pressure in the DHW circuit #3414884
      Value: 7 bar
    27. Create: Max. water pressure in the heating circuit #3414885
      Value: 3 bar
    28. Create: Gas connection #3414886
      Value: 3/4"
    29. Create: Heating circuit connection #3414887
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3414888
      Value: 1/2"
    31. Create: Chimney diameter #3414889
      Value: 60 mm
    32. Create: Coaxial chimney diameter #3414890
      Value: 60/100 mm and 80/125 mm
    33. Create: Connection of a separate chimney diameter 80 mm #3414891
      Value: Yes
    34. Create: Dimensions WxHxD #3414892
      Value: 400x745x315 mm
    35. Create: Weight #3414893
      Value: 28 kg
    36. Create: Image #6323261
      URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id4353887003074118963.jpeg/orig
    37. Create: Image #6323262
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id1828600370029362359.jpeg/orig
    38. Create: Image #6323263
      URL: https://avatars.mds.yandex.net/get-mpic/5313128/img_id6521318310180951938.jpeg/orig
    39. Create: Image #6323264
      URL: https://avatars.mds.yandex.net/get-mpic/4012413/img_id8329055581495113837.jpeg/orig
    40. Create: Preview image #6323265
      URL: https://avatars.mds.yandex.net/get-mpic/4252138/img_id4353887003074118963.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:55
    Name: Boiler Ariston HS X 15 FF NG double-circuit; Catalog: Heating boilers