Change history for item: Boiler Ariston HS X 24 CF NG double-circuit

  1. Donny Darko 08 July 2023 06:24:56
    1. Create: Description #3414796
      Value: Type of heating boiler: gas, max. heating power: 25.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3414797
      Value: Gas, convection
    3. Create: Burner #3414798
      Value: Gas
    4. Create: Number of circuits #3414799
      Value: Double-circuit
    5. Create: Thermal power #3414800
      Value: 11 - 25.80 kW
    6. Create: The combustion chamber #3414801
      Value: Open
    7. Create: Efficiency #3414802
      Value: 92.7 %
    8. Create: Control #3414803
      Value: Electronic
    9. Create: Installation #3414804
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3414805
      Value: Aluminum
    11. Create: Secondary heat exchanger material #3414806
      Value: Copper
    12. Create: Mains voltage #3414807
      Value: Single-phase
    13. Create: Peculiarities #3414808
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3414809
      Value: 8 l
    15. Create: Equipment #3414810
      Value: Built-in blower, display
    16. Create: Fuel #3414811
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3414812
      Value: 2.86 cu. m/hour
    18. Create: LPG consumption #3414813
      Value: 2 kg/hour
    19. Create: Nominal pressure of natural gas #3414814
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3414815
      Value: 37 mbar
    21. Create: Heat carrier temperature #3414816
      Value: 35 - 82 °С
    22. Create: Temperature in the DHW circuit #3414817
      Value: 36 - 60 °С
    23. Create: Hot water capacity at t 25°C #3414818
      Value: 14.3 l/min
    24. Create: Hot water capacity at t 30°C #3414819
      Value: 11.8 l/min
    25. Create: Hot water capacity at t 35°C #3414820
      Value: 10.2 l/min
    26. Create: Max. water pressure in the DHW circuit #3414821
      Value: 7 bar
    27. Create: Max. water pressure in the heating circuit #3414822
      Value: 3 bar
    28. Create: Gas connection #3414823
      Value: 3/4"
    29. Create: Heating circuit connection #3414824
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3414825
      Value: 1/2"
    31. Create: Chimney diameter #3414826
      Value: 125 mm
    32. Create: Dimensions WxHxD #3414827
      Value: 400x745x315 mm
    33. Create: Weight #3414828
      Value: 26 kg
    34. Create: Image #6323246
      URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id6084016780550029551.jpeg/orig
    35. Create: Image #6323247
      URL: https://avatars.mds.yandex.net/get-mpic/4219717/img_id7787196603909970258.jpeg/orig
    36. Create: Image #6323248
      URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id3054890488295415421.jpeg/orig
    37. Create: Preview image #6323249
      URL: https://avatars.mds.yandex.net/get-mpic/4489193/img_id6084016780550029551.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:54
    Name: Boiler Ariston HS X 24 CF NG double-circuit; Catalog: Heating boilers