Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:26:45
Create:
Width #32726
Value: 400
Create:
Height #32727
Value: 745
Create:
The principle of operation of a gas boiler #3415472
Value: Convection
Create:
Combustion chamber type #3415473
Value: Closed
Create:
Accommodation #3415474
Value: Wall
Create:
Max. thermal power #3415475
Value: 32 kW
Create:
Heated area #3415476
Value: 320 m²
Create:
Maximum water pressure in the heating circuit #3415477
Value: 3 bar
Create:
Coaxial chimney diameter #3415478
Value: 60/100 mm
Create:
Depth #3415479
Value: 319 mm
Create:
Image #6323448
URL: https://avatars.mds.yandex.net/get-mpic/5235397/img_id8634085566591243838.jpeg/orig
Create:
Image #6323449
URL: https://avatars.mds.yandex.net/get-mpic/1597983/img_id6262632642838799407.jpeg/orig
Donny Darko 08 July 2023 06:24:08
Create:
Description #3414388
Value: Type of heating boiler: gas, max. heating power: 34.50 kW, number of circuits: single-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3414389
Value: Gas, convection
Create:
Burner #3414390
Value: Gas
Create:
Number of circuits #3414391
Value: Single-loop
Create:
Thermal power #3414392
Value: 15 - 34.50 kW
Create:
Thermal load #3414393
Value: 16.70 - 38.30 kW
Create:
The combustion chamber #3414394
Value: Closed
Create:
Efficiency #3414395
Value: 93.1 %
Create:
Control #3414396
Value: Electronic
Create:
Installation #3414397
Value: Wall-mounted
Create:
Primary heat exchanger material #3414398
Value: Aluminum
Create:
Mains voltage #3414399
Value: Single-phase
Create:
Peculiarities #3414400
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3414401
Value: 8 l
Create:
Equipment #3414402
Value: Display
Create:
Fuel #3414403
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3414404
Value: 3.44 cu. m/hour
Create:
Nominal pressure of natural gas #3414405
Value: 20 mbar
Create:
Permissible LPG pressure #3414406
Value: 37 mbar
Create:
Heat carrier temperature #3414407
Value: 35 - 82 °С
Create:
Max. water pressure in the heating circuit #3414408
Value: 3 bar
Create:
Gas connection #3414409
Value: 3/4"
Create:
Heating circuit connection #3414410
Value: 3/4"
Create:
Dimensions WxHxD #3414411
Value: 400x700x319 mm
Create:
Weight #3414412
Value: 28 kg
Create:
Image #6323150
URL: https://avatars.mds.yandex.net/get-mpic/5086514/img_id6124123650001896855.jpeg/orig
Create:
Image #6323151
URL: https://avatars.mds.yandex.net/get-mpic/5255974/img_id276621984378122963.jpeg/orig
Create:
Image #6323152
URL: https://avatars.mds.yandex.net/get-mpic/1926093/img_id5339826293634956334.jpeg/orig
Create:
Image #6323153
URL: https://avatars.mds.yandex.net/get-mpic/5239537/img_id8035873908868823728.jpeg/orig
Create:
Image #6323154
URL: https://avatars.mds.yandex.net/get-mpic/5234569/img_id1460735685203951482.jpeg/orig
Create:
Image #6323155
URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id8147245044251981061.jpeg/orig
Create:
Image #6323156
URL: https://avatars.mds.yandex.net/get-mpic/1928572/img_id278965545961225578.jpeg/orig
Create:
Image #6323157
URL: https://avatars.mds.yandex.net/get-mpic/4866352/img_id713620523020648179.jpeg/orig
Create:
Preview image #6323158
URL: https://avatars.mds.yandex.net/get-mpic/5086514/img_id6124123650001896855.jpeg/orig
Donny Darko 30 April 2023 08:26:51
Name: Boiler Ariston CLAS X SYSTEM 32 FF NG; Catalog: Heating boilers