Change history for item: Boiler Ariston CLAS X 24 FF NG

  1. Donny Darko 08 July 2023 06:23:38
    1. Create: Description #3414176
      Value: Type of heating boiler: gas, max. heating power: 25.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3414177
      Value: Gas, convection
    3. Create: Burner #3414178
      Value: Gas
    4. Create: Number of circuits #3414179
      Value: Double-circuit
    5. Create: Thermal power #3414180
      Value: 11 - 25.80 kW
    6. Create: Thermal load #3414181
      Value: 12.20 - 28.70 kW
    7. Create: The combustion chamber #3414182
      Value: Closed
    8. Create: Efficiency #3414183
      Value: 93.7 %
    9. Create: Control #3414184
      Value: Electronic
    10. Create: Installation #3414185
      Value: Wall-mounted
    11. Create: Mains voltage #3414186
      Value: Single-phase
    12. Create: Peculiarities #3414187
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3414188
      Value: 8 l
    14. Create: Equipment #3414189
      Value: Display
    15. Create: Fuel #3414190
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3414191
      Value: 2.73 cu. m/hour
    17. Create: LPG consumption #3414192
      Value: 2 kg/hour
    18. Create: Nominal pressure of natural gas #3414193
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3414194
      Value: 37 mbar
    20. Create: Heat carrier temperature #3414195
      Value: 35 - 82 °С
    21. Create: Temperature in the DHW circuit #3414196
      Value: 36 - 60 °С
    22. Create: Hot water capacity at t 25°C #3414197
      Value: 13.5 l/min
    23. Create: Hot water capacity at t 35°C #3414198
      Value: 9.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3414199
      Value: 7 bar
    25. Create: Max. water pressure in the heating circuit #3414200
      Value: 3 bar
    26. Create: Gas connection #3414201
      Value: 3/4"
    27. Create: Heating circuit connection #3414202
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3414203
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3414204
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3414205
      Value: 400x770x319 mm
    31. Create: Weight #3414206
      Value: 29 kg
    32. Create: Image #6323086
      URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id3816231429544769346.jpeg/orig
    33. Create: Image #6323087
      URL: https://avatars.mds.yandex.net/get-mpic/4465823/img_id71592829539453338.jpeg/orig
    34. Create: Image #6323088
      URL: https://avatars.mds.yandex.net/get-mpic/5236090/img_id4000088673032526295.jpeg/orig
    35. Create: Image #6323089
      URL: https://avatars.mds.yandex.net/get-mpic/1514097/img_id5176266406779245978.jpeg/orig
    36. Create: Image #6323090