Change history for item: Boiler Ariston CLAS X 24 CF NG

  1. Donny Darko 08 July 2023 06:23:35
    1. Create: Description #3414145
      Value: Type of heating boiler: gas, max. heating power: 25.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3414146
      Value: Gas, convection
    3. Create: Burner #3414147
      Value: Gas
    4. Create: Number of circuits #3414148
      Value: Double-circuit
    5. Create: Thermal power #3414149
      Value: 11 - 25.80 kW
    6. Create: Thermal load #3414150
      Value: 12.20 - 28.70 kW
    7. Create: The combustion chamber #3414151
      Value: Open
    8. Create: Efficiency #3414152
      Value: 92.7 %
    9. Create: Control #3414153
      Value: Electronic
    10. Create: Installation #3414154
      Value: Wall-mounted
    11. Create: Mains voltage #3414155
      Value: Single-phase
    12. Create: Peculiarities #3414156
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3414157
      Value: 8 l
    14. Create: Equipment #3414158
      Value: Display
    15. Create: Fuel #3414159
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3414160
      Value: 2.86 cu. m/hour
    17. Create: LPG consumption #3414161
      Value: 2.1 kg/hour
    18. Create: Nominal pressure of natural gas #3414162
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3414163
      Value: 37 mbar
    20. Create: Heat carrier temperature #3414164
      Value: 35 - 82 °С
    21. Create: Temperature in the DHW circuit #3414165
      Value: 36 - 60 °С
    22. Create: Hot water capacity at t 25°C #3414166
      Value: 14.3 l/min
    23. Create: Hot water capacity at t 35°C #3414167
      Value: 10.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3414168
      Value: 7 bar
    25. Create: Max. water pressure in the heating circuit #3414169
      Value: 3 bar
    26. Create: Gas connection #3414170
      Value: 3/4"
    27. Create: Heating circuit connection #3414171
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3414172
      Value: 1/2"
    29. Create: Chimney diameter #3414173
      Value: 130 mm
    30. Create: Dimensions WxHxD #3414174
      Value: 400x770x315mm
    31. Create: Weight #3414175
      Value: 27 kg
    32. Create: Image #6323078
      URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id7357813405570265803.jpeg/orig
    33. Create: Image #6323079
      URL: https://avatars.mds.yandex.net/get-mpic/2008488/img_id2649005177923106316.jpeg/orig
    34. Create: Image #6323080
      URL: https://avatars.mds.yandex.net/get-mpic/5236248/img_id789749807849080822.jpeg/orig
    35. Create: Image #6323081
      URL: https://avatars.mds.yandex.net/get-mpic/4465823/img_id71592829539453338.jpeg/orig
    36. Create: Image #6323082
      URL: https://avatars.mds.yandex.net/get-mpic/5236090/img_id4000088673032526295.jpeg/orig
    37. Create: Image #6323083
      URL: https://avatars.mds.yandex.net/get-mpic/1514097/img_id5176266406779245978.jpeg/orig
    38. Create: Image #6323084
      URL: https://avatars.mds.yandex.net/get-mpic/1514097/img_id7975597924239573584.jpeg/orig
    39. Create: Preview image #6323085
      URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id7357813405570265803.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:48
    Name: Boiler Ariston CLAS X 24 CF NG; Catalog: Heating boilers