Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:23:28
Create:
Description #3414081
Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3414082
Value: Gas, convection
Create:
Burner #3414083
Value: Gas
Create:
Number of circuits #3414084
Value: Double-circuit
Create:
Thermal power #3414085
Value: 13 - 30 kW
Create:
Thermal load #3414086
Value: 14.40 - 33.30 kW
Create:
The combustion chamber #3414087
Value: Closed
Create:
Heated area #3414088
Value: 300 sq.m
Create:
Efficiency #3414089
Value: 93.8 %
Create:
Control #3414090
Value: Electronic
Create:
Installation #3414091
Value: Wall-mounted
Create:
Primary heat exchanger material #3414092
Value: Copper
Create:
Mains voltage #3414093
Value: Single-phase
Create:
Peculiarities #3414094
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3414095
Value: 8 l
Create:
Equipment #3414096
Value: Display
Create:
Fuel #3414097
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3414098
Value: 3.17 cu. m/hour
Create:
LPG consumption #3414099
Value: 2.33 kg/hour
Create:
Nominal pressure of natural gas #3414100
Value: 20 mbar
Create:
Permissible LPG pressure #3414101
Value: 37 mbar
Create:
Heat carrier temperature #3414102
Value: 35 - 82 °С
Create:
Temperature in the DHW circuit #3414103
Value: 36 - 60 °С
Create:
Hot water capacity at t 25°C #3414104
Value: 15.7 l/min
Create:
Hot water capacity at t 35°C #3414105
Value: 11.2 l/min
Create:
Max. water pressure in the DHW circuit #3414106
Value: 7 bar
Create:
Max. water pressure in the heating circuit #3414107
Value: 3 bar
Create:
Gas connection #3414108
Value: 3/4"
Create:
Heating circuit connection #3414109
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3414110
Value: 1/2"
Create:
Coaxial chimney diameter #3414111
Value: 60/100 mm
Create:
Dimensions WxHxD #3414112
Value: 400x745x319 mm
Create:
Weight #3414113
Value: 32 kg
Create:
Image #6323069
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id5097027088797497415.jpeg/orig
Create:
Image #6323070
URL: https://avatars.mds.yandex.net/get-mpic/1571231/img_id7163402875803693282.jpeg/orig
Create:
Image #6323071
URL: https://avatars.mds.yandex.net/get-mpic/4055817/img_id919591502749350944.jpeg/orig
Create:
Preview image #6323072
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id5097027088797497415.jpeg/orig
Donny Darko 30 April 2023 08:26:48
Name: Boiler Ariston ALTEAS X 30 FF NG; Catalog: Heating boilers