Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:23:25
Create:
Description #3414048
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3414049
Value: Gas, convection
Create:
Burner #3414050
Value: Gas
Create:
Number of circuits #3414051
Value: Double-circuit
Create:
Thermal power #3414052
Value: 9.50 - 24 kW
Create:
Thermal load #3414053
Value: 11 - 28.70 kW
Create:
The combustion chamber #3414054
Value: Closed
Create:
Heated area #3414055
Value: 240 sq.m
Create:
Efficiency #3414056
Value: 93.7 %
Create:
Control #3414057
Value: Electronic
Create:
Installation #3414058
Value: Wall-mounted
Create:
Primary heat exchanger material #3414059
Value: Copper
Create:
Mains voltage #3414060
Value: Single-phase
Create:
Peculiarities #3414061
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3414062
Value: 8 l
Create:
Equipment #3414063
Value: Display
Create:
Fuel #3414064
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3414065
Value: 2.73 cu. m/hour
Create:
LPG consumption #3414066
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3414067
Value: 20 mbar
Create:
Permissible LPG pressure #3414068
Value: 37 mbar
Create:
Heat carrier temperature #3414069
Value: 35 - 82 °С
Create:
Temperature in the DHW circuit #3414070
Value: 36 - 60 °С
Create:
Hot water capacity at t 25°C #3414071
Value: 13.5 l/min
Create:
Hot water capacity at t 35°C #3414072
Value: 9.6 l/min
Create:
Max. water pressure in the DHW circuit #3414073
Value: 7 bar
Create:
Max. water pressure in the heating circuit #3414074
Value: 3 bar
Create:
Gas connection #3414075
Value: 3/4"
Create:
Heating circuit connection #3414076
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3414077
Value: 1/2"
Create:
Coaxial chimney diameter #3414078
Value: 60/100 mm
Create:
Dimensions WxHxD #3414079
Value: 400x745x319 mm
Create:
Weight #3414080
Value: 31 kg
Create:
Image #6323063
URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id5637144931422743515.jpeg/orig
Create:
Image #6323064
URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id438977712466603393.jpeg/orig
Create:
Image #6323065
URL: https://avatars.mds.yandex.net/get-mpic/7937668/img_id7955930393137677069.jpeg/orig
Create:
Image #6323066
URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id495263224308227097.jpeg/orig
Create:
Image #6323067
URL: https://avatars.mds.yandex.net/get-mpic/4559636/img_id4660042633448673268.jpeg/orig
Create:
Preview image #6323068
URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id5637144931422743515.jpeg/orig
Donny Darko 30 April 2023 08:26:47
Name: Boiler Ariston ALTEAS X 24 FF NG; Catalog: Heating boilers