Change history for item: Boiler Ariston CARES X 18 FF NG

  1. Donny Darko 08 July 2023 06:23:13
    1. Create: Description #3413947
      Value: Type of heating boiler: gas, max. thermal power: 19 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3413948
      Value: Gas, convection
    3. Create: Burner #3413949
      Value: Gas
    4. Create: Number of circuits #3413950
      Value: Double-circuit
    5. Create: Thermal power #3413951
      Value: 11 - 19 kW
    6. Create: Thermal load #3413952
      Value: 12.20 - 21.10 kW
    7. Create: The combustion chamber #3413953
      Value: Closed
    8. Create: Heated area #3413954
      Value: 180 sq.m
    9. Create: Efficiency #3413955
      Value: 93.8 %
    10. Create: Control #3413956
      Value: Electronic
    11. Create: Installation #3413957
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3413958
      Value: Copper
    13. Create: Secondary heat exchanger material #3413959
      Value: Stainless steel
    14. Create: Mains voltage #3413960
      Value: Single-phase
    15. Create: Peculiarities #3413961
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    16. Create: Expansion tank volume #3413962
      Value: 8 l
    17. Create: Equipment #3413963
      Value: Display
    18. Create: Fuel #3413964
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3413965
      Value: 2.01 cu. m/hour
    20. Create: LPG consumption #3413966
      Value: 1.48 kg/hour
    21. Create: Nominal pressure of natural gas #3413967
      Value: 20 mbar
    22. Create: Permissible LPG pressure #3413968
      Value: 37 mbar
    23. Create: Heat carrier temperature #3413969
      Value: 35 - 82 °С
    24. Create: Temperature in the DHW circuit #3413970
      Value: 36 - 60 °С
    25. Create: Hot water capacity at t 25°C #3413971
      Value: 13.5 l/min
    26. Create: Hot water capacity at t 35°C #3413972
      Value: 9.6 l/min
    27. Create: Max. water pressure in the DHW circuit #3413973
      Value: 7 bar
    28. Create: Max. water pressure in the heating circuit #3413974
      Value: 3 bar
    29. Create: Gas connection #3413975
      Value: 3/4"
    30. Create: Heating circuit connection #3413976
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3413977
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3413978
      Value: 60/100 mm
    33. Create: Dimensions WxHxD #3413979
      Value: 400x700x319 mm
    34. Create: Weight #3413980
      Value: 28 kg
    35. Create: Image #6323040
      URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id8222729913333689398.jpeg/orig
    36. Create: Image #6323041
      URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id4017554936482311982.jpeg/orig
    37. Create: Image #6323042
      URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id4033967381201856230.jpeg/orig
    38. Create: Preview image #6323043
      URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id8222729913333689398.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:46
    Name: Boiler Ariston CARES X 18 FF NG; Catalog: Heating boilers