Change history for item: Boiler Ariston CARES PREMIUM 30 28.4 kW double-circuit

  1. Donny Darko 08 July 2023 06:23:00
    1. Create: Description #3413856
      Value: Type of heating boiler: gas, max. heating power: 28.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3413857
      Value: Gas, condensing
    3. Create: Burner #3413858
      Value: Gas
    4. Create: Number of circuits #3413859
      Value: Double-circuit
    5. Create: Thermal power #3413860
      Value: 5.80 - 28.40 kW
    6. Create: Thermal load #3413861
      Value: 6 - 29 kW
    7. Create: The combustion chamber #3413862
      Value: Closed
    8. Create: Efficiency #3413863
      Value: 104 %
    9. Create: Control #3413864
      Value: Electronic
    10. Create: Installation #3413865
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3413866
      Value: Aluminum
    12. Create: Mains voltage #3413867
      Value: Single-phase
    13. Create: Peculiarities #3413868
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3413869
      Value: 8 l
    15. Create: Equipment #3413870
      Value: Display
    16. Create: Fuel #3413871
      Value: Natural gas, liquefied gas
    17. Create: Heat carrier temperature #3413872
      Value: 25 - 82 °С
    18. Create: Temperature in the DHW circuit #3413873
      Value: 36 - 60 °С
    19. Create: Hot water capacity at t 25°C #3413874
      Value: 16.3 l/min
    20. Create: Hot water capacity at t 35°C #3413875
      Value: 11.6 l/min
    21. Create: Max. water pressure in the DHW circuit #3413876
      Value: 7 bar
    22. Create: Max. water pressure in the heating circuit #3413877
      Value: 3 bar
    23. Create: Gas connection #3413878
      Value: 3/4"
    24. Create: Heating circuit connection #3413879
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3413880
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3413881
      Value: 60/100 mm and 80/125 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3413882
      Value: Yes
    28. Create: Dimensions WxHxD #3413883
      Value: 400x745x319 mm
    29. Create: Weight #3413884
      Value: 32 kg
    30. Create: Image #6323018
      URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id4634046635614097364.jpeg/orig
    31. Create: Preview image #6323019
      URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id4634046635614097364.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:46
    Name: Boiler Ariston CARES PREMIUM 30 28.4 kW double-circuit; Catalog: Heating boilers