Change history for item: Boiler Ariston GENUS 28 CF 29.5 kW double-circuit

  1. Donny Darko 08 July 2023 06:22:32
    1. Create: Description #3413650
      Value: Type of heating boiler: gas, max. heating power: 29.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3413651
      Value: Gas, convection
    3. Create: Burner #3413652
      Value: Gas
    4. Create: Number of circuits #3413653
      Value: Double-circuit
    5. Create: Thermal power #3413654
      Value: 13 - 29.50 kW
    6. Create: The combustion chamber #3413655
      Value: Open
    7. Create: Efficiency #3413656
      Value: 92.3 %
    8. Create: Control #3413657
      Value: Electronic
    9. Create: Installation #3413658
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3413659
      Value: Copper
    11. Create: Secondary heat exchanger material #3413660
      Value: Stainless steel
    12. Create: Mains voltage #3413661
      Value: Single-phase
    13. Create: Peculiarities #3413662
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3413663
      Value: 8 l
    15. Create: Equipment #3413664
      Value: Display
    16. Create: Fuel #3413665
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3413666
      Value: 3.12 cu. m/hour
    18. Create: LPG consumption #3413667
      Value: 2.32 kg/h
    19. Create: Nominal pressure of natural gas #3413668
      Value: 5 - 20 mbar
    20. Create: Permissible LPG pressure #3413669
      Value: 37 mbar
    21. Create: Heat carrier temperature #3413670
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3413671
      Value: 36 - 60 °С
    23. Create: Hot water capacity at t 25°C #3413672
      Value: 16.2 l/min
    24. Create: Hot water capacity at t 30°C #3413673
      Value: 11.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3413674
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3413675
      Value: 3 bar
    27. Create: Gas connection #3413676
      Value: 3/4"
    28. Create: Heating circuit connection #3413677
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3413678
      Value: 1/2"
    30. Create: Chimney diameter #3413679
      Value: 125 mm
    31. Create: Dimensions WxHxD #3413680
      Value: 400x770x315mm
    32. Create: Weight #3413681
      Value: 31 kg
    33. Create: Image #6323003
      URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id4075800288570983943.jpeg/orig
    34. Create: Preview image #6323004
      URL: https://avatars.mds.yandex.net/get-mpic/4346078/img_id4075800288570983943.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:44
    Name: Boiler Ariston GENUS 28 CF 29.5 kW double-circuit; Catalog: Heating boilers