Change history for item: Boiler Ariston GENUS PREMIUM 35 30 kW double-circuit

  1. Donny Darko 08 July 2023 06:21:33
    1. Create: Description #3413189
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3413190
      Value: Gas, condensing
    3. Create: Burner #3413191
      Value: Gas
    4. Create: Number of circuits #3413192
      Value: Double-circuit
    5. Create: Thermal power #3413193
      Value: 6 - 30 kW
    6. Create: Thermal load #3413194
      Value: 7 - 31 kW
    7. Create: The combustion chamber #3413195
      Value: Closed
    8. Create: Efficiency #3413196
      Value: 106.9 %
    9. Create: Control #3413197
      Value: Electronic
    10. Create: Installation #3413198
      Value: Wall-mounted
    11. Create: Mains voltage #3413199
      Value: Single-phase
    12. Create: Peculiarities #3413200
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3413201
      Value: 8 l
    14. Create: Equipment #3413202
      Value: Display, room thermostat
    15. Create: Fuel #3413203
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3413204
      Value: 3.28 cu. m/hour
    17. Create: LPG consumption #3413205
      Value: 2.41 kg/h
    18. Create: Heat carrier temperature #3413206
      Value: 20 - 82 °С
    19. Create: Temperature in the DHW circuit #3413207
      Value: 36 - 60 °С
    20. Create: Hot water capacity at t 25°C #3413208
      Value: 20 l/min
    21. Create: Hot water capacity at t 30°C #3413209
      Value: 16.7 l/min
    22. Create: Hot water capacity at t 35°C #3413210
      Value: 14.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3413211
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3413212
      Value: 3 bar
    25. Create: Gas connection #3413213
      Value: 3/4"
    26. Create: Heating circuit connection #3413214
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3413215
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3413216
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3413217
      Value: Yes
    30. Create: Dimensions WxHxD #3413218
      Value: 440x745x385 mm
    31. Create: Weight #3413219
      Value: 35.5 kg
    32. Create: Image #6322956
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id660929089893391828/orig
    33. Create: Preview image #6322957
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id660929089893391828/orig
  2. Donny Darko 30 April 2023 08:26:39
    Name: Boiler Ariston GENUS PREMIUM 35 30 kW double-circuit; Catalog: Heating boilers