Change history for item: Boiler Ariston GENUS PREMIUM 24 21 kW double-circuit

  1. Donny Darko 08 July 2023 06:21:27
    1. Create: Description #3413127
      Value: Type of heating boiler: gas, max. thermal power: 21 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3413128
      Value: Gas, condensing
    3. Create: Burner #3413129
      Value: Gas
    4. Create: Number of circuits #3413130
      Value: Double-circuit
    5. Create: Thermal power #3413131
      Value: 5 - 21 kW
    6. Create: Thermal load #3413132
      Value: 5.50 - 22 kW
    7. Create: The combustion chamber #3413133
      Value: Closed
    8. Create: Efficiency #3413134
      Value: 107 %
    9. Create: Control #3413135
      Value: Electronic
    10. Create: Installation #3413136
      Value: Wall-mounted
    11. Create: Mains voltage #3413137
      Value: Single-phase
    12. Create: Peculiarities #3413138
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3413139
      Value: 8 l
    14. Create: Equipment #3413140
      Value: Display, room thermostat
    15. Create: Fuel #3413141
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3413142
      Value: 2.33 cu. m/hour
    17. Create: LPG consumption #3413143
      Value: 1.71 kg/h
    18. Create: Heat carrier temperature #3413144
      Value: 20 - 82 °С
    19. Create: Temperature in the DHW circuit #3413145
      Value: 36 - 60 °С
    20. Create: Hot water capacity at t 25°C #3413146
      Value: 14.4 l/min
    21. Create: Hot water capacity at t 30°C #3413147
      Value: 12 l/min
    22. Create: Hot water capacity at t 35°C #3413148
      Value: 10.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3413149
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3413150
      Value: 3 bar
    25. Create: Gas connection #3413151
      Value: 3/4"
    26. Create: Heating circuit connection #3413152
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3413153
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3413154
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3413155
      Value: Yes
    30. Create: Dimensions WxHxD #3413156
      Value: 440x745x385 mm
    31. Create: Weight #3413157
      Value: 32 kg
    32. Create: Image #6322952
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id660929089893391828/orig
    33. Create: Preview image #6322953
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id660929089893391828/orig
  2. Donny Darko 30 April 2023 08:26:39
    Name: Boiler Ariston GENUS PREMIUM 24 21 kW double-circuit; Catalog: Heating boilers