Change history for item: Boiler Ariston BS II 24 CF 23.7 kW double-circuit

  1. Donny Darko 08 July 2023 06:20:24
    1. Create: Description #3412671
      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3412672
      Value: Gas, convection
    3. Create: Burner #3412673
      Value: Gas
    4. Create: Number of circuits #3412674
      Value: Double-circuit
    5. Create: Thermal power #3412675
      Value: 10.10 - 23.70 kW
    6. Create: Thermal load #3412676
      Value: 11.20 - 25.80 kW
    7. Create: The combustion chamber #3412677
      Value: Open
    8. Create: Efficiency #3412678
      Value: 91.9 %
    9. Create: Control #3412679
      Value: Electronic
    10. Create: Installation #3412680
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3412681
      Value: Copper
    12. Create: Mains voltage #3412682
      Value: Single-phase
    13. Create: Peculiarities #3412683
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer, water filter
    14. Create: Expansion tank volume #3412684
      Value: 8 l
    15. Create: Fuel #3412685
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3412686
      Value: 2.73 cu. m/hour
    17. Create: LPG consumption #3412687
      Value: 2.03 kg/h
    18. Create: Nominal pressure of natural gas #3412688
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3412689
      Value: 30 mbar
    20. Create: Heat carrier temperature #3412690
      Value: 35 - 85 °С
    21. Create: Temperature in the DHW circuit #3412691
      Value: 36 - 65 °С
    22. Create: Hot water capacity at t 25°C #3412692
      Value: 13.6 l/min
    23. Create: Hot water capacity at t 35°C #3412693
      Value: 9.7 l/min
    24. Create: Max. water pressure in the DHW circuit #3412694
      Value: 7 bar
    25. Create: Max. water pressure in the heating circuit #3412695
      Value: 3 bar
    26. Create: Gas connection #3412696
      Value: 3/4"
    27. Create: Heating circuit connection #3412697
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3412698
      Value: 1/2"
    29. Create: Chimney diameter #3412699
      Value: 125 mm
    30. Create: Dimensions WxHxD #3412700
      Value: 400x770x315mm
    31. Create: Weight #3412701
      Value: 30 kg
    32. Create: Image #6322904
      URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id2902192883137906985.jpeg/orig
    33. Create: Preview image #6322905
      URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id2902192883137906985.jpeg/orig
  2. Donny Darko 30 April 2023 08:26:34
    Name: Boiler Ariston BS II 24 CF 23.7 kW double-circuit; Catalog: Heating boilers