Change history for item: Boiler Ariston CLAS 24 CF

  1. Donny Darko 08 July 2023 06:20:02
    1. Create: Description #3412483
      Value: Type of heating boiler: gas, max. heating power: 25.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3412484
      Value: Gas, convection
    3. Create: Burner #3412485
      Value: Gas
    4. Create: Number of circuits #3412486
      Value: Double-circuit
    5. Create: Thermal power #3412487
      Value: 11.20 - 25.80 kW
    6. Create: The combustion chamber #3412488
      Value: Open
    7. Create: Efficiency #3412489
      Value: 93 %
    8. Create: Control #3412490
      Value: Electronic
    9. Create: Installation #3412491
      Value: Wall-mounted
    10. Create: Mains voltage #3412492
      Value: Single-phase
    11. Create: Peculiarities #3412493
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    12. Create: Expansion tank volume #3412494
      Value: 8 l
    13. Create: Equipment #3412495
      Value: Display
    14. Create: Fuel #3412496
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3412497
      Value: 2.9 cu. m/hour
    16. Create: LPG consumption #3412498
      Value: 2.2 kg/hour
    17. Create: Nominal pressure of natural gas #3412499
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3412500
      Value: 37 mbar
    19. Create: Heat carrier temperature #3412501
      Value: 35 - 85 °С
    20. Create: Temperature in the DHW circuit #3412502
      Value: 36 - 60 °С
    21. Create: Hot water capacity at t 25°C #3412503
      Value: 14.6 l/min
    22. Create: Hot water capacity at t 30°C #3412504
      Value: 12.2 l/min
    23. Create: Hot water capacity at t 35°C #3412505
      Value: 10.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3412506
      Value: 7 bar
    25. Create: Max. water pressure in the heating circuit #3412507
      Value: 3 bar
    26. Create: Gas connection #3412508
      Value: 3/4"
    27. Create: Heating circuit connection #3412509
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3412510
      Value: 1/2"
    29. Create: Chimney diameter #3412511
      Value: 125 mm
    30. Create: Dimensions WxHxD #3412512
      Value: 400x770x315mm
    31. Create: Weight #3412513
      Value: 30 kg
    32. Create: Image #6322892
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8460462637154353313/orig
    33. Create: Preview image #6322893
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8460462637154353313/orig
  2. Donny Darko 30 April 2023 08:26:31
    Name: Boiler Ariston CLAS 24 CF; Catalog: Heating boilers