Change history for item: Gas E.C.A. Gelios 16 HM

  1. Donny Darko 08 July 2023 06:11:47
    1. Create: Description #3409802
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3409803
      Value: Gas, convection
    3. Create: Burner #3409804
      Value: Gas
    4. Create: Number of circuits #3409805
      Value: Double-circuit
    5. Create: Thermal power #3409806
      Value: 8.20 - 16 kW
    6. Create: Thermal load #3409807
      Value: 9.20 - 17.88 kW
    7. Create: The combustion chamber #3409808
      Value: Closed
    8. Create: Efficiency #3409809
      Value: 93 %
    9. Create: Control #3409810
      Value: Electronic
    10. Create: Installation #3409811
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3409812
      Value: Copper
    12. Create: Mains voltage #3409813
      Value: Single-phase
    13. Create: Peculiarities #3409814
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3409815
      Value: 6 l
    15. Create: Equipment #3409816
      Value: Display
    16. Create: Fuel #3409817
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3409818
      Value: 1.93 cu. m/hour
    18. Create: Nominal pressure of natural gas #3409819
      Value: 13 - 20 mbar
    19. Create: Heat carrier temperature #3409820
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3409821
      Value: 35 - 64 °С
    21. Create: Max. water pressure in the DHW circuit #3409822
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3409823
      Value: 3 bar
    23. Create: Gas connection #3409824
      Value: 3/4"
    24. Create: Heating circuit connection #3409825
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3409826
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3409827
      Value: 60/100 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3409828
      Value: Yes
    28. Create: Dimensions WxHxD #3409829
      Value: 400x720x330 mm
    29. Create: Weight #3409830
      Value: 30 kg
    30. Create: Image #6322533
      URL: https://avatars.mds.yandex.net/get-mpic/3916156/img_id310337209658862553.jpeg/orig
    31. Create: Preview image #6322534
      URL: https://avatars.mds.yandex.net/get-mpic/3916156/img_id310337209658862553.jpeg/orig
  2. Donny Darko 30 April 2023 08:25:50
    Name: Gas E.C.A. Gelios 16 HM; Catalog: Heating boilers