Change history for item: Gas E.C.A. Helios 11 HM

  1. Donny Darko 08 July 2023 06:11:42
    1. Create: Description #3409773
      Value: Type of heating boiler: gas, max. heat output: 11.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3409774
      Value: Gas, convection
    3. Create: Burner #3409775
      Value: Gas
    4. Create: Number of circuits #3409776
      Value: Double-circuit
    5. Create: Thermal power #3409777
      Value: 8.20 - 11.30 kW
    6. Create: Thermal load #3409778
      Value: 9.20 - 12.81 kW
    7. Create: The combustion chamber #3409779
      Value: Closed
    8. Create: Efficiency #3409780
      Value: 93 %
    9. Create: Control #3409781
      Value: Electronic
    10. Create: Installation #3409782
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3409783
      Value: Copper
    12. Create: Mains voltage #3409784
      Value: Single-phase
    13. Create: Peculiarities #3409785
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3409786
      Value: 6 l
    15. Create: Equipment #3409787
      Value: Display
    16. Create: Fuel #3409788
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3409789
      Value: 1.38 cu. m/hour
    18. Create: Nominal pressure of natural gas #3409790
      Value: 13 - 20 mbar
    19. Create: Heat carrier temperature #3409791
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3409792
      Value: 35 - 64 °С
    21. Create: Max. water pressure in the DHW circuit #3409793
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3409794
      Value: 3 bar
    23. Create: Gas connection #3409795
      Value: 3/4"
    24. Create: Heating circuit connection #3409796
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3409797
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3409798
      Value: 60/100 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3409799
      Value: Yes
    28. Create: Dimensions WxHxD #3409800
      Value: 400x720x330 mm
    29. Create: Weight #3409801
      Value: 30 kg