Change history for item: Gas E.C.A. Fortius 24 HB 24 kW dual circuit

  1. Donny Darko 08 July 2023 06:11:26
    1. Create: Description #3409660
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3409661
      Value: Gas, convection
    3. Create: Burner #3409662
      Value: Gas
    4. Create: Number of circuits #3409663
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3409664
      Value: 8.40 - 24 kW
    6. Create: Thermal load #3409665
      Value: 9.20 - 26.20 kW
    7. Create: The combustion chamber #3409666
      Value: Closed
    8. Create: Control #3409667
      Value: Electronic
    9. Create: Installation #3409668
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3409669
      Value: Copper
    11. Create: Mains voltage #3409670
      Value: Single-phase
    12. Create: Peculiarities #3409671
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3409672
      Value: 8 l
    14. Create: Equipment #3409673
      Value: Display
    15. Create: Fuel #3409674
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3409675
      Value: 2.73 cu. m/hour
    17. Create: LPG consumption #3409676
      Value: 2.08 kg/hour
    18. Create: Nominal pressure of natural gas #3409677
      Value: 13 mbar
    19. Create: Permissible LPG pressure #3409678
      Value: 30 mbar
    20. Create: Heat carrier temperature #3409679
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3409680
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 35°C #3409681
      Value: 10 l/min
    23. Create: Max. water pressure in the DHW circuit #3409682
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3409683
      Value: 3 bar
    25. Create: Gas connection #3409684
      Value: 3/4"
    26. Create: Heating circuit connection #3409685
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3409686
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3409687
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3409688
      Value: Yes
    30. Create: Dimensions WxHxD #3409689
      Value: 454x750x340 mm
    31. Create: Weight #3409690
      Value: 39.8 kg
    32. Create: Image #6322523
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id6593195290921903388/orig
    33. Create: Preview image #6322524
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id6593195290921903388/orig
  2. Donny Darko 30 April 2023 08:25:48
    Name: Gas E.C.A. Fortius 24 HB 24 kW dual circuit; Catalog: Heating boilers