Change history for item: Gas E.C.A. Confeo Plus 24 HM 23.4 kW dual circuit

  1. Donny Darko 08 July 2023 06:10:51
    1. Create: Description #3409463
      Value: Type of heating boiler: gas, max. heating power: 23.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3409464
      Value: Gas, convection
    3. Create: Burner #3409465
      Value: Gas
    4. Create: Number of circuits #3409466
      Value: Double-circuit
    5. Create: Thermal power #3409467
      Value: 8.30 - 23.40 kW
    6. Create: Thermal load #3409468
      Value: 9.20 - 25.40 kW
    7. Create: The combustion chamber #3409469
      Value: Closed
    8. Create: Control #3409470
      Value: Electronic
    9. Create: Installation #3409471
      Value: Wall-mounted
    10. Create: Mains voltage #3409472
      Value: Single-phase
    11. Create: Peculiarities #3409473
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3409474
      Value: 8 l
    13. Create: Equipment #3409475
      Value: Display
    14. Create: Fuel #3409476
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3409477
      Value: 2.65 cu. m/hour
    16. Create: Nominal pressure of natural gas #3409478
      Value: 20 mbar
    17. Create: Permissible LPG pressure #3409479
      Value: 30 mbar
    18. Create: Heat carrier temperature #3409480
      Value: 35 - 80 °С
    19. Create: Temperature in the DHW circuit #3409481
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 35°C #3409482
      Value: 10 l/min
    21. Create: Max. water pressure in the DHW circuit #3409483
      Value: 10 bar
    22. Create: Max. water pressure in the heating circuit #3409484
      Value: 3 bar
    23. Create: Gas connection #3409485
      Value: 3/4"
    24. Create: Heating circuit connection #3409486
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3409487
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3409488
      Value: 60/100 mm and 80/125 mm
    27. Create: Dimensions WxHxD #3409489
      Value: 454x750x340 mm
    28. Create: Weight #3409490
      Value: 40.3 kg
    29. Create: Image #6322509
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id1389824801495618781/orig
    30. Create: Preview image #6322510
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id1389824801495618781/orig
  2. Donny Darko 30 April 2023 08:25:46
    Name: Gas E.C.A. Confeo Plus 24 HM 23.4 kW dual circuit; Catalog: Heating boilers