Change history for item: Gas E.C.A. Calora 28 HM 28 kW dual circuit

  1. Donny Darko 08 July 2023 06:10:08
    1. Create: Description #3409266
      Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3409267
      Value: Gas, convection
    3. Create: Burner #3409268
      Value: Gas
    4. Create: Number of circuits #3409269
      Value: Double-circuit
    5. Create: Thermal power #3409270
      Value: 9.80 - 28 kW
    6. Create: Thermal load #3409271
      Value: 10.70 - 30.60 kW
    7. Create: The combustion chamber #3409272
      Value: Closed
    8. Create: Control #3409273
      Value: Electronic
    9. Create: Installation #3409274
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3409275
      Value: Copper
    11. Create: Mains voltage #3409276
      Value: Single-phase
    12. Create: Peculiarities #3409277
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3409278
      Value: 8 l
    14. Create: Equipment #3409279
      Value: Display
    15. Create: Fuel #3409280
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3409281
      Value: 3.19 cu. m/hour
    17. Create: LPG consumption #3409282
      Value: 2.39 kg/hour
    18. Create: Nominal pressure of natural gas #3409283
      Value: 13 mbar
    19. Create: Permissible LPG pressure #3409284
      Value: 30 mbar
    20. Create: Heat carrier temperature #3409285
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3409286
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 35°C #3409287
      Value: 12 l/min
    23. Create: Max. water pressure in the DHW circuit #3409288
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3409289
      Value: 3 bar
    25. Create: Gas connection #3409290
      Value: 3/4"
    26. Create: Heating circuit connection #3409291
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3409292
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3409293
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3409294
      Value: Yes
    30. Create: Dimensions WxHxD #3409295
      Value: 454x750x340 mm
    31. Create: Weight #3409296
      Value: 41.3 kg
    32. Create: Image #6322495
      URL: https://avatars.mds.yandex.net/get-mpic/3923571/img_id1851522991752421245.jpeg/orig
    33. Create: Preview image #6322496
      URL: https://avatars.mds.yandex.net/get-mpic/3923571/img_id1851522991752421245.jpeg/orig
  2. Donny Darko 30 April 2023 08:25:44
    Name: Gas E.C.A. Calora 28 HM 28 kW dual circuit; Catalog: Heating boilers