Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 06:10:03
Create:
Description #3409235
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3409236
Value: Gas, convection
Create:
Burner #3409237
Value: Gas
Create:
Number of circuits #3409238
Value: Double-circuit
Create:
Thermal power #3409239
Value: 8.40 - 24 kW
Create:
Thermal load #3409240
Value: 9.20 - 26.20 kW
Create:
The combustion chamber #3409241
Value: Closed
Create:
Control #3409242
Value: Electronic
Create:
Installation #3409243
Value: Wall-mounted
Create:
Primary heat exchanger material #3409244
Value: Copper
Create:
Mains voltage #3409245
Value: Single-phase
Create:
Peculiarities #3409246
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3409247
Value: 8 l
Create:
Equipment #3409248
Value: Display
Create:
Fuel #3409249
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3409250
Value: 2.73 cu. m/hour
Create:
LPG consumption #3409251
Value: 2.08 kg/hour
Create:
Nominal pressure of natural gas #3409252
Value: 13 mbar
Create:
Permissible LPG pressure #3409253
Value: 30 mbar
Create:
Heat carrier temperature #3409254
Value: 40 - 80 °С
Create:
Temperature in the DHW circuit #3409255
Value: 35 - 60 °С
Create:
Hot water capacity at t 35°C #3409256
Value: 10 l/min
Create:
Max. water pressure in the DHW circuit #3409257
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3409258
Value: 3 bar
Create:
Gas connection #3409259
Value: 3/4"
Create:
Heating circuit connection #3409260
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3409261
Value: 1/2"
Create:
Coaxial chimney diameter #3409262
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3409263
Value: Yes
Create:
Dimensions WxHxD #3409264
Value: 454x750x340 mm
Create:
Weight #3409265
Value: 40.8 kg
Create:
Image #6322493
URL: https://avatars.mds.yandex.net/get-mpic/4448884/img_id9119189308424900275.jpeg/orig
Create:
Preview image #6322494
URL: https://avatars.mds.yandex.net/get-mpic/4448884/img_id9119189308424900275.jpeg/orig
Donny Darko 30 April 2023 08:25:43
Name: Gas E.C.A. Calora 24 HM 24 kW dual circuit; Catalog: Heating boilers