Change history for item: Gas E.C.A. Calora 24 BB 24 kW dual circuit

  1. Donny Darko 08 July 2023 06:09:52
    1. Create: Description #3409175
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3409176
      Value: Gas, convection
    3. Create: Burner #3409177
      Value: Gas
    4. Create: Number of circuits #3409178
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3409179
      Value: 8.40 - 24 kW
    6. Create: Thermal load #3409180
      Value: 9.30 - 26.60 kW
    7. Create: The combustion chamber #3409181
      Value: Open
    8. Create: Control #3409182
      Value: Electronic
    9. Create: Installation #3409183
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3409184
      Value: Copper
    11. Create: Mains voltage #3409185
      Value: Single-phase
    12. Create: Peculiarities #3409186
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3409187
      Value: 8 l
    14. Create: Equipment #3409188
      Value: Display
    15. Create: Fuel #3409189
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3409190
      Value: 2.77 cu. m/hour
    17. Create: LPG consumption #3409191
      Value: 2.08 kg/hour
    18. Create: Nominal pressure of natural gas #3409192
      Value: 13 mbar
    19. Create: Permissible LPG pressure #3409193
      Value: 30 mbar
    20. Create: Heat carrier temperature #3409194
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3409195
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 35°C #3409196
      Value: 10 l/min
    23. Create: Max. water pressure in the DHW circuit #3409197
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3409198
      Value: 3 bar
    25. Create: Gas connection #3409199
      Value: 3/4"
    26. Create: Heating circuit connection #3409200
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3409201
      Value: 1/2"
    28. Create: Dimensions WxHxD #3409202
      Value: 454x750x340 mm
    29. Create: Weight #3409203
      Value: 337 kg
    30. Create: Image #6322489
      URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id903805319749555273.jpeg/orig
    31. Create: Preview image #6322490
      URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id903805319749555273.jpeg/orig
  2. Donny Darko 30 April 2023 08:25:43
    Name: Gas E.C.A. Calora 24 BB 24 kW dual circuit; Catalog: Heating boilers