Change history for item: Gas E.C.A. Confeo Premix 35 HM 33 kW double circuit

  1. Donny Darko 08 July 2023 06:09:16
    1. Create: Description #3409032
      Value: Type of heating boiler: gas, max. thermal power: 33 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3409033
      Value: Gas, condensing
    3. Create: Burner #3409034
      Value: Gas
    4. Create: Number of circuits #3409035
      Value: Double-circuit
    5. Create: Thermal power #3409036
      Value: 9.90 - 33 kW
    6. Create: Thermal load #3409037
      Value: 9.50 - 32.30 kW
    7. Create: The combustion chamber #3409038
      Value: Closed
    8. Create: Control #3409039
      Value: Electronic
    9. Create: Installation #3409040
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3409041
      Value: Stainless steel
    11. Create: Mains voltage #3409042
      Value: Single-phase
    12. Create: Peculiarities #3409043
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3409044
      Value: 10 l
    14. Create: Equipment #3409045
      Value: Display
    15. Create: Fuel #3409046
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3409047
      Value: 3.47 cu. m/hour
    17. Create: LPG consumption #3409048
      Value: 2.6 kg/hour
    18. Create: Nominal pressure of natural gas #3409049
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3409050
      Value: 37 mbar
    20. Create: Heat carrier temperature #3409051
      Value: 30 - 80 °С
    21. Create: Temperature in the DHW circuit #3409052
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 30°C #3409053
      Value: 15.8 l/min
    23. Create: Hot water capacity at t 35°C #3409054
      Value: 14.7 l/min
    24. Create: Max. water pressure in the DHW circuit #3409055
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3409056
      Value: 3 bar
    26. Create: Gas connection #3409057
      Value: 3/4"
    27. Create: Heating circuit connection #3409058
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3409059
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3409060
      Value: 80/125 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3409061
      Value: Yes
    31. Create: Dimensions WxHxD #3409062
      Value: 454x750x365 mm
    32. Create: Weight #3409063
      Value: 45 kg
    33. Create: Image #6322475
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id6374055447656357380.jpeg/orig
    34. Create: Preview image #6322476
      URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id6374055447656357380.jpeg/orig
  2. Donny Darko 30 April 2023 08:25:40
    Name: Gas E.C.A. Confeo Premix 35 HM 33 kW double circuit; Catalog: Heating boilers