Change history for item: Gas Alphatherm Sigma PKD 24U

  1. Donny Darko 08 July 2023 05:42:19
    1. Create: Description #3400794
      Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3400795
      Value: Gas, convection
    3. Create: Burner #3400796
      Value: Gas
    4. Create: Number of circuits #3400797
      Value: Double-circuit
    5. Create: Thermal power #3400798
      Value: 9.90 - 22.90 kW
    6. Create: Thermal load #3400799
      Value: 11.50 - 25.50 kW
    7. Create: The combustion chamber #3400800
      Value: Open
    8. Create: Efficiency #3400801
      Value: 92.4 %
    9. Create: Control #3400802
      Value: Electronic
    10. Create: Installation #3400803
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3400804
      Value: Copper
    12. Create: Mains voltage #3400805
      Value: Single-phase
    13. Create: Peculiarities #3400806
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3400807
      Value: 6 l
    15. Create: Equipment #3400808
      Value: Display
    16. Create: Fuel #3400809
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3400810
      Value: 2.7 cu. m/hour
    18. Create: LPG consumption #3400811
      Value: 1.98 kg/hour
    19. Create: Nominal pressure of natural gas #3400812
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3400813
      Value: 37 mbar
    21. Create: Heat carrier temperature #3400814
      Value: 45 - 78 °С
    22. Create: Temperature in the DHW circuit #3400815
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3400816
      Value: 13.7 l/min
    24. Create: Hot water capacity at t 30°C #3400817
      Value: 11.4 l/min
    25. Create: Hot water capacity at t 35°C #3400818
      Value: 9.8 l/min
    26. Create: Hot water capacity at t 40°C #3400819
      Value: 8.6 l/min
    27. Create: Hot water capacity at t 45°C #3400820
      Value: 7.8 l/min
    28. Create: Max. water pressure in the DHW circuit #3400821
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3400822
      Value: 3 bar
    30. Create: Gas connection #3400823
      Value: 3/4"
    31. Create: Heating circuit connection #3400824
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3400825
      Value: 1/2"
    33. Create: Chimney diameter #3400826
      Value: 130 mm
    34. Create: Dimensions WxHxD #3400827
      Value: 420x700x255mm
    35. Create: Weight #3400828
      Value: 35 kg
    36. Create: Image #6321559
      URL: https://avatars.mds.yandex.net/get-mpic/3699895/img_id5707597470088268507.jpeg/orig
    37. Create: Preview image #6321560
      URL: https://avatars.mds.yandex.net/get-mpic/3699895/img_id5707597470088268507.jpeg/orig
  2. Donny Darko 30 April 2023 08:23:41
    Name: Gas Alphatherm Sigma PKD 24U; Catalog: Heating boilers