Change history for item: Gas Alphatherm Sigma BT 18U 18.5 kW double-circuit

  1. Donny Darko 08 July 2023 05:42:15
    1. Create: Description #3400758
      Value: Type of heating boiler: gas, max. heating power: 18.50 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3400759
      Value: Gas, convection
    3. Create: Burner #3400760
      Value: Gas
    4. Create: Number of circuits #3400761
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3400762
      Value: 7.80 - 18.50 kW
    6. Create: Thermal load #3400763
      Value: 9 - 20.50 kW
    7. Create: The combustion chamber #3400764
      Value: Closed
    8. Create: Efficiency #3400765
      Value: 92.4 %
    9. Create: Control #3400766
      Value: Electronic
    10. Create: Installation #3400767
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3400768
      Value: Copper
    12. Create: Mains voltage #3400769
      Value: Single-phase
    13. Create: Peculiarities #3400770
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3400771
      Value: 6 l
    15. Create: Equipment #3400772
      Value: Display
    16. Create: Fuel #3400773
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3400774
      Value: 2.17 cu. m/hour
    18. Create: LPG consumption #3400775
      Value: 1.59 kg/hour
    19. Create: Nominal pressure of natural gas #3400776
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3400777
      Value: 37 mbar
    21. Create: Heat carrier temperature #3400778
      Value: 45 - 78 °С
    22. Create: Temperature in the DHW circuit #3400779
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3400780
      Value: 10.1 l/min
    24. Create: Hot water capacity at t 30°C #3400781
      Value: 8.43 l/min
    25. Create: Hot water capacity at t 35°C #3400782
      Value: 7.22 l/min
    26. Create: Hot water capacity at t 40°C #3400783
      Value: 6.32 l/min
    27. Create: Hot water capacity at t 45°C #3400784
      Value: 5.3 l/min
    28. Create: Max. water pressure in the DHW circuit #3400785
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3400786
      Value: 3 bar
    30. Create: Gas connection #3400787
      Value: 3/4"
    31. Create: Heating circuit connection #3400788
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3400789
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3400790
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3400791
      Value: Yes
    35. Create: Dimensions WxHxD #3400792
      Value: 420x700x255mm
    36. Create: Weight #3400793
      Value: 36 kg
    37. Create: Image #6321557
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id9075650906117818198.jpeg/orig
    38. Create: Preview image #6321558
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id9075650906117818198.jpeg/orig
  2. Donny Darko 30 April 2023 08:23:41
    Name: Gas Alphatherm Sigma BT 18U 18.5 kW double-circuit; Catalog: Heating boilers