Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:42:10
Create:
Description #3400722
Value: Type of heating boiler: gas, max. heating power: 24.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3400723
Value: Gas, convection
Create:
Burner #3400724
Value: Gas
Create:
Number of circuits #3400725
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3400726
Value: 10.10 - 24.60 kW
Create:
Thermal load #3400727
Value: 11.50 - 26.50 kW
Create:
The combustion chamber #3400728
Value: Closed
Create:
Efficiency #3400729
Value: 92.92 %
Create:
Control #3400730
Value: Electronic
Create:
Installation #3400731
Value: Wall-mounted
Create:
Primary heat exchanger material #3400732
Value: Copper
Create:
Mains voltage #3400733
Value: Single-phase
Create:
Peculiarities #3400734
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3400735
Value: 6 l
Create:
Equipment #3400736
Value: Display
Create:
Fuel #3400737
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3400738
Value: 2.8 cu. m/hour
Create:
LPG consumption #3400739
Value: 2.06 kg/h
Create:
Nominal pressure of natural gas #3400740
Value: 20 mbar
Create:
Permissible LPG pressure #3400741
Value: 37 mbar
Create:
Heat carrier temperature #3400742
Value: 45 - 78 °С
Create:
Temperature in the DHW circuit #3400743
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3400744
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3400745
Value: 11.4 l/min
Create:
Hot water capacity at t 35°C #3400746
Value: 9.8 l/min
Create:
Hot water capacity at t 40°C #3400747
Value: 8.6 l/min
Create:
Hot water capacity at t 45°C #3400748
Value: 7.6 l/min
Create:
Max. water pressure in the DHW circuit #3400749
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3400750
Value: 3 bar
Create:
Gas connection #3400751
Value: 3/4"
Create:
Heating circuit connection #3400752
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3400753
Value: 1/2"
Create:
Coaxial chimney diameter #3400754
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3400755
Value: Yes
Create:
Dimensions WxHxD #3400756
Value: 420x700x255mm
Create:
Weight #3400757
Value: 36 kg
Create:
Image #6321555
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id6154896346841455191.jpeg/orig
Create:
Preview image #6321556
URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id6154896346841455191.jpeg/orig
Donny Darko 30 April 2023 08:23:40
Name: Gas Alphatherm Sigma BT 24U 24.6 kW double-circuit; Catalog: Heating boilers