Change history for item: Gas Alphatherm Sigma BK 24U

  1. Donny Darko 08 July 2023 05:42:02
    1. Create: Description #3400653
      Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3400654
      Value: Gas, convection
    3. Create: Burner #3400655
      Value: Gas
    4. Create: Number of circuits #3400656
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3400657
      Value: 9.90 - 22.90 kW
    6. Create: Thermal load #3400658
      Value: 11.50 - 25.50 kW
    7. Create: The combustion chamber #3400659
      Value: Open
    8. Create: Efficiency #3400660
      Value: 89.9 %
    9. Create: Control #3400661
      Value: Electronic
    10. Create: Installation #3400662
      Value: Wall-mounted
    11. Create: Mains voltage #3400663
      Value: Single-phase
    12. Create: Peculiarities #3400664
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3400665
      Value: 6 l
    14. Create: Equipment #3400666
      Value: Outdoor temperature sensor, display
    15. Create: Fuel #3400667
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3400668
      Value: 2.7 cu. m/hour
    17. Create: LPG consumption #3400669
      Value: 1.98 kg/hour
    18. Create: Nominal pressure of natural gas #3400670
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3400671
      Value: 37 mbar
    20. Create: Heat carrier temperature #3400672
      Value: 45 - 78 °С
    21. Create: Temperature in the DHW circuit #3400673
      Value: 35 - 57 °С
    22. Create: Hot water capacity at t 25°C #3400674
      Value: 10.11 l/min
    23. Create: Hot water capacity at t 30°C #3400675
      Value: 8.43 l/min
    24. Create: Hot water capacity at t 35°C #3400676
      Value: 7.22 l/min
    25. Create: Hot water capacity at t 40°C #3400677
      Value: 6.32 l/min
    26. Create: Hot water capacity at t 45°C #3400678
      Value: 5.3 l/min
    27. Create: Max. water pressure in the heating circuit #3400679
      Value: 3 bar
    28. Create: Gas connection #3400680
      Value: 3/4"
    29. Create: Heating circuit connection #3400681
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3400682
      Value: 1/2"
    31. Create: Chimney diameter #3400683
      Value: 130 mm
    32. Create: Dimensions WxHxD #3400684
      Value: 420x700x255mm
    33. Create: Weight #3400685
      Value: 35 kg
    34. Create: Image #6321551
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id6212129909752091408.jpeg/orig
    35. Create: Preview image #6321552
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id6212129909752091408.jpeg/orig
  2. Donny Darko 30 April 2023 08:23:40
    Name: Gas Alphatherm Sigma BK 24U; Catalog: Heating boilers