Change history for item: Gas Alphatherm Sigma PTD 24U

  1. Donny Darko 08 July 2023 05:41:57
    1. Create: Description #3400620
      Value: Type of heating boiler: gas, max. heating power: 24.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3400621
      Value: Gas, convection
    3. Create: Burner #3400622
      Value: Gas
    4. Create: Number of circuits #3400623
      Value: Double-circuit
    5. Create: Thermal power #3400624
      Value: 10.10 - 24.60 kW
    6. Create: Thermal load #3400625
      Value: 11.50 - 26.50 kW
    7. Create: The combustion chamber #3400626
      Value: Closed
    8. Create: Efficiency #3400627
      Value: 93.05 %
    9. Create: Control #3400628
      Value: Electronic
    10. Create: Installation #3400629
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3400630
      Value: Copper
    12. Create: Mains voltage #3400631
      Value: Single-phase
    13. Create: Peculiarities #3400632
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3400633
      Value: 6 l
    15. Create: Equipment #3400634
      Value: Display
    16. Create: Fuel #3400635
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3400636
      Value: 2.8 cu. m/hour
    18. Create: LPG consumption #3400637
      Value: 2.06 kg/h
    19. Create: Nominal pressure of natural gas #3400638
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3400639
      Value: 37 mbar
    21. Create: Heat carrier temperature #3400640
      Value: 45 - 78 °С
    22. Create: Temperature in the DHW circuit #3400641
      Value: 35 - 57 °С
    23. Create: Hot water capacity at t 25°C #3400642
      Value: 13.7 l/min
    24. Create: Hot water capacity at t 30°C #3400643
      Value: 11.4 l/min
    25. Create: Hot water capacity at t 35°C #3400644
      Value: 9.8 l/min
    26. Create: Hot water capacity at t 40°C #3400645
      Value: 8.6 l/min
    27. Create: Max. water pressure in the DHW circuit #3400646
      Value: 6 bar
    28. Create: Max. water pressure in the heating circuit #3400647
      Value: 3 bar
    29. Create: Gas connection #3400648
      Value: 3/4"
    30. Create: Heating circuit connection #3400649
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3400650
      Value: 1/2"
    32. Create: Dimensions WxHxD #3400651
      Value: 420x700x255mm
    33. Create: Weight #3400652
      Value: 36 kg
    34. Create: Image #6321549
      URL: https://avatars.mds.yandex.net/get-mpic/4032259/img_id1989308893807275809.jpeg/orig
    35. Create: Preview image #6321550
      URL: https://avatars.mds.yandex.net/get-mpic/4032259/img_id1989308893807275809.jpeg/orig
  2. Donny Darko 30 April 2023 08:23:39
    Name: Gas Alphatherm Sigma PTD 24U; Catalog: Heating boilers