Change history for item: Gas Alphatherm Sigma PTD 32U 32.3 kW double-circuit

  1. Donny Darko 08 July 2023 05:41:48
    1. Create: Description #3400556
      Value: Type of heating boiler: gas, max. heating power: 32.30 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3400557
      Value: Gas, convection
    3. Create: Burner #3400558
      Value: Gas
    4. Create: Number of circuits #3400559
      Value: Double-circuit
    5. Create: Thermal power #3400560
      Value: 12.20 - 32.30 kW
    6. Create: Thermal load #3400561
      Value: 13.50 - 34.50 kW
    7. Create: The combustion chamber #3400562
      Value: Closed
    8. Create: Efficiency #3400563
      Value: 93.5 %
    9. Create: Control #3400564
      Value: Electronic
    10. Create: Installation #3400565
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3400566
      Value: Copper
    12. Create: Mains voltage #3400567
      Value: Single-phase
    13. Create: Peculiarities #3400568
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3400569
      Value: 10 l
    15. Create: Equipment #3400570
      Value: Display
    16. Create: Fuel #3400571
      Value: Natural gas, liquefied gas
    17. Create: Nominal pressure of natural gas #3400572
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3400573
      Value: 37 mbar
    19. Create: Heat carrier temperature #3400574
      Value: 45 - 78 °С
    20. Create: Temperature in the DHW circuit #3400575
      Value: 35 - 57 °С
    21. Create: Hot water capacity at t 35°C #3400576
      Value: 13.19 l/min
    22. Create: Hot water capacity at t 40°C #3400577
      Value: 11.55 l/min
    23. Create: Hot water capacity at t 45°C #3400578
      Value: 10.26 l/min
    24. Create: Max. water pressure in the DHW circuit #3400579
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3400580
      Value: 3 bar
    26. Create: Gas connection #3400581
      Value: 3/4"
    27. Create: Heating circuit connection #3400582
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3400583
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3400584
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3400585
      Value: Yes
    31. Create: Dimensions WxHxD #3400586
      Value: 420x700x345mm
    32. Create: Weight #3400587
      Value: 37 kg
    33. Create: Image #6321545
      URL: https://avatars.mds.yandex.net/get-mpic/4977172/img_id4741234074305498668.jpeg/orig
    34. Create: Preview image #6321546
      URL: https://avatars.mds.yandex.net/get-mpic/4977172/img_id4741234074305498668.jpeg/orig
  2. Donny Darko 30 April 2023 08:23:39
    Name: Gas Alphatherm Sigma PTD 32U 32.3 kW double-circuit; Catalog: Heating boilers