Change history for item: Gas Alphatherm Sigma Eco PTD 24 24 kW double-circuit

  1. Donny Darko 08 July 2023 05:41:36
    1. Create: Description #3400469
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3400470
      Value: Gas, convection
    3. Create: Burner #3400471
      Value: Gas
    4. Create: Number of circuits #3400472
      Value: Double-circuit
    5. Create: Thermal power #3400473
      Value: 11.20 - 24 kW
    6. Create: The combustion chamber #3400474
      Value: Closed
    7. Create: Efficiency #3400475
      Value: 91 %
    8. Create: Control #3400476
      Value: Electronic
    9. Create: Installation #3400477
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3400478
      Value: Copper
    11. Create: Mains voltage #3400479
      Value: Single-phase
    12. Create: Peculiarities #3400480
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3400481
      Value: 6 l
    14. Create: Equipment #3400482
      Value: Display
    15. Create: Fuel #3400483
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3400484
      Value: 2.4 cu. m/hour
    17. Create: LPG consumption #3400485
      Value: 0.79 kg/h
    18. Create: Heat carrier temperature #3400486
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3400487
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 25°C #3400488
      Value: 12 l/min
    21. Create: Hot water capacity at t 30°C #3400489
      Value: 10 l/min
    22. Create: Max. water pressure in the DHW circuit #3400490
      Value: 8 bar
    23. Create: Max. water pressure in the heating circuit #3400491
      Value: 2.5 bar
    24. Create: Gas connection #3400492
      Value: 3/4"
    25. Create: Heating circuit connection #3400493
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3400494
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3400495
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3400496
      Value: 400x740x305mm
    29. Create: Weight #3400497
      Value: 37 kg
    30. Create: Image #6321539
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id8797511877588902544/orig
    31. Create: Preview image #6321540
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id8797511877588902544/orig
  2. Donny Darko 30 April 2023 08:23:38
    Name: Gas Alphatherm Sigma Eco PTD 24 24 kW double-circuit; Catalog: Heating boilers