Change history for item: Gas Alphatherm Beta ATEB 42

  1. Donny Darko 08 July 2023 05:41:31
    1. Create: Description #3400436
      Value: Type of heating boiler: gas, max. heating power: 42.54 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3400437
      Value: Gas, convection
    3. Create: Burner #3400438
      Value: Gas
    4. Create: Number of circuits #3400439
      Value: Double-circuit
    5. Create: Max. thermal power #3400440
      Value: 42.54 kW
    6. Create: Max. thermal load #3400441
      Value: 47 kW
    7. Create: The combustion chamber #3400442
      Value: Open
    8. Create: Efficiency #3400443
      Value: 90.51 %
    9. Create: Control #3400444
      Value: Electronic
    10. Create: Installation #3400445
      Value: Floor
    11. Create: Primary heat exchanger material #3400446
      Value: Cast iron
    12. Create: Mains voltage #3400447
      Value: Single-phase
    13. Create: Peculiarities #3400448
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
    14. Create: The volume of the built-in boiler #3400449
      Value: 60 l
    15. Create: Expansion tank volume #3400450
      Value: 18 l
    16. Create: Equipment #3400451
      Value: Built-in boiler, display
    17. Create: Fuel #3400452
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3400453
      Value: 4.97 cu. m/hour
    19. Create: LPG consumption #3400454
      Value: 3.7 kg/hour
    20. Create: Nominal pressure of natural gas #3400455
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3400456
      Value: 29 mbar
    22. Create: Heat carrier temperature #3400457
      Value: 40 - 90 °С
    23. Create: Temperature in the DHW circuit #3400458
      Value: 50 - 65 °С
    24. Create: Hot water capacity at t 30°C #3400459
      Value: 22 l/min
    25. Create: Max. water pressure in the DHW circuit #3400460
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3400461
      Value: 3 bar
    27. Create: Gas connection #3400462
      Value: 1/2"
    28. Create: Heating circuit connection #3400463
      Value: 1"
    29. Create: Branch pipe for connecting the DHW circuit #3400464
      Value: 3/4"
    30. Create: Chimney diameter #3400465
      Value: 150 mm
    31. Create: Dimensions WxHxD #3400466
      Value: 600x1370x800mm
    32. Create: Weight #3400467
      Value: 206 kg
    33. Create: Additional Information #3400468
      Value: The volume of the expansion tank in the DHW system - 5 l
    34. Create: Image #6321537
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5120006040327638129/orig
    35. Create: Preview image #6321538
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id5120006040327638129/orig
  2. Donny Darko 30 April 2023 08:23:38
    Name: Gas Alphatherm Beta ATEB 42; Catalog: Heating boilers