Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:38:06
Create:
Description #3399521
Value: Type of heating boiler: gas, max. heating power: 25.05 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
Create:
Type of heating boiler #3399522
Value: Gas, convection
Create:
Burner #3399523
Value: Gas
Create:
Number of circuits #3399524
Value: Double-circuit
Create:
Max. thermal power #3399525
Value: 25.05 kW
Create:
Max. thermal load #3399526
Value: 27.87 kW
Create:
The combustion chamber #3399527
Value: Open
Create:
Efficiency #3399528
Value: 89.9 %
Create:
Control #3399529
Value: Electronic
Create:
Installation #3399530
Value: Floor
Create:
Primary heat exchanger material #3399531
Value: Cast iron
Create:
Secondary heat exchanger material #3399532
Value: Stainless steel
Create:
Mains voltage #3399533
Value: Single-phase
Create:
Peculiarities #3399534
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3399535
Value: 60 l
Create:
Expansion tank volume #3399536
Value: 12 l
Create:
Equipment #3399537
Value: Built-in boiler, display
Create:
Fuel #3399538
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3399539
Value: 2.95 cu. m/hour
Create:
LPG consumption #3399540
Value: 2.2 kg/hour
Create:
Nominal pressure of natural gas #3399541
Value: 20 mbar
Create:
Permissible LPG pressure #3399542
Value: 29 mbar
Create:
Heat carrier temperature #3399543
Value: 40 - 90 °С
Create:
Temperature in the DHW circuit #3399544
Value: 65 - 50 °C
Create:
Hot water capacity at t 30°C #3399545
Value: 22 l/min
Create:
Max. water pressure in the DHW circuit #3399546
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3399547
Value: 3 bar
Create:
Gas connection #3399548
Value: 1/2"
Create:
Heating circuit connection #3399549
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3399550
Value: 3/4"
Create:
Chimney diameter #3399551
Value: 130 mm
Create:
Dimensions WxHxD #3399552
Value: 600x1370x800mm
Create:
Weight #3399553
Value: 172 kg
Create:
Image #6321445
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
Create:
Image #6321446
URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id8450076250138870632/orig
Create:
Preview image #6321447
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
Donny Darko 30 April 2023 08:23:25
Name: Gas Fondital Bali BTNE 25 25.05 kW double-circuit; Catalog: Heating boilers