Change history for item: Gas wall-mounted FORMENTERA PLUS CTFS 32

  1. Donny Darko 08 July 2023 05:37:34
    1. Create: Non-volatile #3399298
      Value: There is
    2. Create: Efficiency #3399299
      Value: 93.4 %
    3. Create: Minimum heating medium temperature #3399300
      Value: 35°C
    4. Create: Chimney diameter #3399301
      Value: 100 mm
    5. Create: Minimum temperature in the DHW circuit #3399302
      Value: 35°C
    6. Create: Image #6321405
      URL: https://avatars.mds.yandex.net/get-mpic/4592225/img_id5946691607022668560.jpeg/orig
    7. Create: Image #6321406
      URL: https://avatars.mds.yandex.net/get-mpic/5332179/img_id8529153226994897755.jpeg/orig
    8. Create: Image #6321407
      URL: https://avatars.mds.yandex.net/get-mpic/5238586/img_id7936326257527752866.png/orig
  2. Donny Darko 08 July 2023 05:37:30
    1. Create: Description #3399265
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3399266
      Value: Gas
    3. Create: Number of circuits #3399267
      Value: Double-circuit
    4. Create: The principle of operation of a gas boiler #3399268
      Value: Convection
    5. Create: Combustion chamber type #3399269
      Value: Closed
    6. Create: Primary heat exchanger material #3399270
      Value: Copper
    7. Create: Accommodation #3399271
      Value: Wall
    8. Create: Power type #3399272
      Value: Single-phase
    9. Create: Control #3399273
      Value: Electronic
    10. Create: Equipment #3399274
      Value: Built-in exhaust fan, display
    11. Create: Functions #3399275
      Value: Self-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, equipment for working with a solar collector system, heat connection
    12. Create: Minimum heat output #3399276
      Value: 16 kW
    13. Create: Max. thermal power #3399277
      Value: 33 kW
    14. Create: Minimum heat load #3399278
      Value: 14.3 kW
    15. Create: Maximum thermal load #3399279
      Value: 30.8 kW
    16. Create: Heated area #3399280
      Value: 300 m²
    17. Create: Maximum water pressure in the heating circuit #3399281
      Value: 3 bar
    18. Create: Maximum coolant temperature #3399282
      Value: 83°C
    19. Create: Expansion tank volume #3399283
      Value: 7 l
    20. Create: Gas connection #3399284
      Value: 1/2"
    21. Create: Heating circuit connection #3399285
      Value: 3/4"
    22. Create: Branch pipe for connecting the DHW circuit #3399286
      Value: 1/2"
    23. Create: Coaxial chimney diameter #3399287
      Value: 60/100 mm
    24. Create: Burner #3399288
      Value: Gas
    25. Create: Secondary heat exchanger material #3399289
      Value: Stainless steel
    26. Create: Maximum temperature in the DHW circuit #3399290
      Value: 62°C
    27. Create: Maximum water pressure in the DHW circuit #3399291
      Value: 6 bar
    28. Create: Fuel #3399292
      Value: Natural gas
    29. Create: Hot water capacity at t 30°C #3399293
      Value: 15.1 l/min
    30. Create: Nominal natural gas pressure min. #3399294
      Value: 13 mbar
    31. Create: Natural gas consumption #3399295
      Value: 3.49 m³/h
    32. Create: Depth #3399296
      Value: 315 mm
    33. Create: Weight #3399297
      Value: 38.5 kg
    34. Create: Image #6321402
      URL: https://avatars.mds.yandex.net/get-mpic/4794494/img_id1488130782107300024.jpeg/orig
    35. Create: Image #6321403
      URL: https://avatars.mds.yandex.net/get-mpic/5209949/img_id6799040631048168651.jpeg/orig
    36. Create: Preview image #6321404
      URL: https://avatars.mds.yandex.net/get-mpic/4794494/img_id1488130782107300024.jpeg/orig
  3. Donny Darko 30 April 2023 08:23:23
    Name: Gas wall-mounted FORMENTERA PLUS CTFS 32; Catalog: Heating boilers