Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:37:34
Create:
Non-volatile #3399298
Value: There is
Create:
Efficiency #3399299
Value: 93.4 %
Create:
Minimum heating medium temperature #3399300
Value: 35°C
Create:
Chimney diameter #3399301
Value: 100 mm
Create:
Minimum temperature in the DHW circuit #3399302
Value: 35°C
Create:
Image #6321405
URL: https://avatars.mds.yandex.net/get-mpic/4592225/img_id5946691607022668560.jpeg/orig
Create:
Image #6321406
URL: https://avatars.mds.yandex.net/get-mpic/5332179/img_id8529153226994897755.jpeg/orig
Create:
Image #6321407
URL: https://avatars.mds.yandex.net/get-mpic/5238586/img_id7936326257527752866.png/orig
Donny Darko 08 July 2023 05:37:30
Create:
Description #3399265
Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3399266
Value: Gas
Create:
Number of circuits #3399267
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3399268
Value: Convection
Create:
Combustion chamber type #3399269
Value: Closed
Create:
Primary heat exchanger material #3399270
Value: Copper
Create:
Accommodation #3399271
Value: Wall
Create:
Power type #3399272
Value: Single-phase
Create:
Control #3399273
Value: Electronic
Create:
Equipment #3399274
Value: Built-in exhaust fan, display
Create:
Functions #3399275
Value: Self-diagnostics, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation, equipment for working with a solar collector system, heat connection
Create:
Minimum heat output #3399276
Value: 16 kW
Create:
Max. thermal power #3399277
Value: 33 kW
Create:
Minimum heat load #3399278
Value: 14.3 kW
Create:
Maximum thermal load #3399279
Value: 30.8 kW
Create:
Heated area #3399280
Value: 300 m²
Create:
Maximum water pressure in the heating circuit #3399281
Value: 3 bar
Create:
Maximum coolant temperature #3399282
Value: 83°C
Create:
Expansion tank volume #3399283
Value: 7 l
Create:
Gas connection #3399284
Value: 1/2"
Create:
Heating circuit connection #3399285
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3399286
Value: 1/2"
Create:
Coaxial chimney diameter #3399287
Value: 60/100 mm
Create:
Burner #3399288
Value: Gas
Create:
Secondary heat exchanger material #3399289
Value: Stainless steel
Create:
Maximum temperature in the DHW circuit #3399290
Value: 62°C
Create:
Maximum water pressure in the DHW circuit #3399291
Value: 6 bar
Create:
Fuel #3399292
Value: Natural gas
Create:
Hot water capacity at t 30°C #3399293
Value: 15.1 l/min
Create:
Nominal natural gas pressure min. #3399294
Value: 13 mbar
Create:
Natural gas consumption #3399295
Value: 3.49 m³/h
Create:
Depth #3399296
Value: 315 mm
Create:
Weight #3399297
Value: 38.5 kg
Create:
Image #6321402
URL: https://avatars.mds.yandex.net/get-mpic/4794494/img_id1488130782107300024.jpeg/orig
Create:
Image #6321403
URL: https://avatars.mds.yandex.net/get-mpic/5209949/img_id6799040631048168651.jpeg/orig
Create:
Preview image #6321404
URL: https://avatars.mds.yandex.net/get-mpic/4794494/img_id1488130782107300024.jpeg/orig
Donny Darko 30 April 2023 08:23:23
Name: Gas wall-mounted FORMENTERA PLUS CTFS 32; Catalog: Heating boilers