Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:36:55
Create:
Description #3399015
Value: Type of heating boiler: gas, max. heating power: 23.31 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3399016
Value: Gas, convection
Create:
Burner #3399017
Value: Gas
Create:
Number of circuits #3399018
Value: Double-circuit
Create:
Thermal power #3399019
Value: 9.85 - 23.31 kW
Create:
Max. thermal load #3399020
Value: 25.70 kW
Create:
The combustion chamber #3399021
Value: Open
Create:
Efficiency #3399022
Value: 90.7 %
Create:
Control #3399023
Value: Electronic
Create:
Installation #3399024
Value: Wall-mounted
Create:
Primary heat exchanger material #3399025
Value: Copper
Create:
Secondary heat exchanger material #3399026
Value: Stainless steel
Create:
Mains voltage #3399027
Value: Single-phase
Create:
Peculiarities #3399028
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3399029
Value: 25 l
Create:
Expansion tank volume #3399030
Value: 8 l
Create:
Equipment #3399031
Value: Built-in boiler, display
Create:
Fuel #3399032
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3399033
Value: 2.72 cu. m/hour
Create:
LPG consumption #3399034
Value: 1.99 kg/hour
Create:
Nominal pressure of natural gas #3399035
Value: 13 - 29 mbar
Create:
Permissible LPG pressure #3399036
Value: 37 mbar
Create:
Heat carrier temperature #3399037
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3399038
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3399039
Value: 13.4 l/min
Create:
Hot water capacity at t 30°C #3399040
Value: 11.1 l/min
Create:
Hot water capacity at t 35°C #3399041
Value: 9.5 l/min
Create:
Hot water capacity at t 40°C #3399042
Value: 8.4 l/min
Create:
Hot water capacity at t 45°C #3399043
Value: 7.4 l/min
Create:
Max. water pressure in the DHW circuit #3399044
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3399045
Value: 3 bar
Create:
Gas connection #3399046
Value: 3/4"
Create:
Heating circuit connection #3399047
Value: 1/2"
Create:
Branch pipe for connecting the DHW circuit #3399048
Value: 1/2"
Create:
Chimney diameter #3399049
Value: 130 mm
Create:
Dimensions WxHxD #3399050
Value: 450x750x534 mm
Create:
Additional Information #3399051
Value: DHW filter; DHW circulation pump; DHW safety valve; DHW expansion tank volume: 2 liters
Create:
Image #6321369
URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id3598625767120542082/orig
Create:
Preview image #6321370
URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id3598625767120542082/orig
Donny Darko 30 April 2023 08:23:21
Name: Gas Fondital Nias Dual Line Tech BTN 24 23.31 kW double-circuit; Catalog: Heating boilers