Value: Type of heating boiler: gas, max. thermal power: 30.63 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3398758
Value: Gas, condensing
Create:
Burner #3398759
Value: Gas
Create:
Number of circuits #3398760
Value: Double-circuit
Create:
Thermal power #3398761
Value: 8.70 - 30.63 kW
Create:
Max. thermal load #3398762
Value: 31.40 kW
Create:
The combustion chamber #3398763
Value: Closed
Create:
Efficiency #3398764
Value: 105.4 %
Create:
Control #3398765
Value: Electronic
Create:
Installation #3398766
Value: Wall-mounted
Create:
Primary heat exchanger material #3398767
Value: Stainless steel
Create:
Secondary heat exchanger material #3398768
Value: Stainless steel
Create:
Mains voltage #3398769
Value: Single-phase
Create:
Peculiarities #3398770
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3398771
Value: 10 l
Create:
Equipment #3398772
Value: Display
Create:
Fuel #3398773
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3398774
Value: 3.32 cu. m/hour
Create:
LPG consumption #3398775
Value: 2.44 kg/hour
Create:
Nominal pressure of natural gas #3398776
Value: 20 mbar
Create:
Permissible LPG pressure #3398777
Value: 37 mbar
Create:
Heat carrier temperature #3398778
Value: 20 - 78 °С
Create:
Temperature in the DHW circuit #3398779
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3398780
Value: 20.3 l/min
Create:
Hot water capacity at t 30°C #3398781
Value: 16.9 l/min
Create:
Hot water capacity at t 35°C #3398782
Value: 14.5 l/min
Create:
Hot water capacity at t 40°C #3398783
Value: 12.7 l/min
Create:
Hot water capacity at t 45°C #3398784
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3398785
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3398786
Value: 3 bar
Create:
Gas connection #3398787
Value: 3/4"
Create:
Heating circuit connection #3398788
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3398789
Value: 1/2"
Create:
Coaxial chimney diameter #3398790
Value: 60/100 mm and 80/125 mm
Create:
Connection of a separate chimney diameter 80 mm #3398791
Value: Yes
Create:
Dimensions WxHxD #3398792
Value: 450x750x325mm
Create:
Weight #3398793
Value: 40 kg
Create:
Additional Information #3398794
Value: DHW anti-freeze function
Create:
Image #6321345
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2104809656343156421/orig
Create:
Preview image #6321346
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2104809656343156421/orig
Donny Darko 30 April 2023 08:23:18
Name: Gas Fondital Tahiti Condensing Line Tech KC 32 30.63 kW double-circuit; Catalog: Heating boilers