Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:36:05
Create:
Description #3398603
Value: Type of heating boiler: gas, max. heating power: 28.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3398604
Value: Gas, convection
Create:
Burner #3398605
Value: Gas
Create:
Number of circuits #3398606
Value: Double-circuit
Create:
Thermal power #3398607
Value: 10 - 28.40 kW
Create:
Max. thermal load #3398608
Value: 30.50 kW
Create:
The combustion chamber #3398609
Value: Closed
Create:
Efficiency #3398610
Value: 93.1 %
Create:
Control #3398611
Value: Electronic
Create:
Installation #3398612
Value: Wall-mounted
Create:
Primary heat exchanger material #3398613
Value: Copper
Create:
Secondary heat exchanger material #3398614
Value: Stainless steel
Create:
Mains voltage #3398615
Value: Single-phase
Create:
Peculiarities #3398616
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3398617
Value: 25 l
Create:
Expansion tank volume #3398618
Value: 10 l
Create:
Equipment #3398619
Value: Built-in boiler, display
Create:
Fuel #3398620
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3398621
Value: 3.23 cu. m/hour
Create:
LPG consumption #3398622
Value: 2.37 kg/h
Create:
Nominal pressure of natural gas #3398623
Value: 13 - 29 mbar
Create:
Permissible LPG pressure #3398624
Value: 37 mbar
Create:
Heat carrier temperature #3398625
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3398626
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3398627
Value: 16.3 l/min
Create:
Hot water capacity at t 30°C #3398628
Value: 13.6 l/min
Create:
Hot water capacity at t 35°C #3398629
Value: 11.6 l/min
Create:
Hot water capacity at t 40°C #3398630
Value: 10.2 l/min
Create:
Hot water capacity at t 45°C #3398631
Value: 9 l/min
Create:
Max. water pressure in the DHW circuit #3398632
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3398633
Value: 3 bar
Create:
Gas connection #3398634
Value: 3/4"
Create:
Heating circuit connection #3398635
Value: 1/2"
Create:
Branch pipe for connecting the DHW circuit #3398636
Value: 1/2"
Create:
Coaxial chimney diameter #3398637
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3398638
Value: Yes
Create:
Dimensions WxHxD #3398639
Value: 450x750x534 mm
Create:
Weight #3398640
Value: 67 kg
Create:
Additional Information #3398641
Value: DHW filter; DHW circulation pump; DHW safety valve; DHW expansion tank volume: 2 liters
Create:
Image #6321337
URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id3598625767120542082/orig
Create:
Preview image #6321338
URL: https://avatars.mds.yandex.net/get-mpic/1453843/img_id3598625767120542082/orig
Donny Darko 30 April 2023 08:23:17
Name: Gas Fondital Nias Dual Line Tech BTFS 28 28.4 kW double-circuit; Catalog: Heating boilers