Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:34:09
Create:
Description #3397777
Value: Type of heating boiler: gas, max. thermal power: 31.40 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3397778
Value: Gas, convection
Create:
Burner #3397779
Value: Gas
Create:
Number of circuits #3397780
Value: Double-circuit
Create:
Max. thermal power #3397781
Value: 31.40 kW
Create:
Max. thermal load #3397782
Value: 34.80 kW
Create:
The combustion chamber #3397783
Value: Open
Create:
Efficiency #3397784
Value: 90.22 %
Create:
Control #3397785
Value: Electronic
Create:
Installation #3397786
Value: Floor
Create:
Primary heat exchanger material #3397787
Value: Cast iron
Create:
Secondary heat exchanger material #3397788
Value: Stainless steel
Create:
Mains voltage #3397789
Value: Single-phase
Create:
Peculiarities #3397790
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3397791
Value: 60 l
Create:
Expansion tank volume #3397792
Value: 12 l
Create:
Equipment #3397793
Value: Built-in boiler, display
Create:
Fuel #3397794
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3397795
Value: 3.7 cu. m/hour
Create:
LPG consumption #3397796
Value: 2.76 kg/hour
Create:
Nominal pressure of natural gas #3397797
Value: 20 mbar
Create:
Permissible LPG pressure #3397798
Value: 29 mbar
Create:
Heat carrier temperature #3397799
Value: 40 - 90 °С
Create:
Temperature in the DHW circuit #3397800
Value: 65 - 50 °C
Create:
Hot water capacity at t 30°C #3397801
Value: 24.2 l/min
Create:
Max. water pressure in the DHW circuit #3397802
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3397803
Value: 3 bar
Create:
Gas connection #3397804
Value: 1/2"
Create:
Heating circuit connection #3397805
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3397806
Value: 3/4"
Create:
Chimney diameter #3397807
Value: 150 mm
Create:
Dimensions WxHxD #3397808
Value: 600x1370x800mm
Create:
Weight #3397809
Value: 180.5 kg
Create:
Image #6321258
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
Create:
Image #6321259
URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id8450076250138870632/orig
Create:
Preview image #6321260
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
Donny Darko 30 April 2023 08:23:08
Name: Gas Fondital Bali BTNE 32 31.4 kW double-circuit; Catalog: Heating boilers