Change history for item: Gas Fondital Bali BTNE 32 31.4 kW double-circuit

  1. Donny Darko 08 July 2023 05:34:09
    1. Create: Description #3397777
      Value: Type of heating boiler: gas, max. thermal power: 31.40 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3397778
      Value: Gas, convection
    3. Create: Burner #3397779
      Value: Gas
    4. Create: Number of circuits #3397780
      Value: Double-circuit
    5. Create: Max. thermal power #3397781
      Value: 31.40 kW
    6. Create: Max. thermal load #3397782
      Value: 34.80 kW
    7. Create: The combustion chamber #3397783
      Value: Open
    8. Create: Efficiency #3397784
      Value: 90.22 %
    9. Create: Control #3397785
      Value: Electronic
    10. Create: Installation #3397786
      Value: Floor
    11. Create: Primary heat exchanger material #3397787
      Value: Cast iron
    12. Create: Secondary heat exchanger material #3397788
      Value: Stainless steel
    13. Create: Mains voltage #3397789
      Value: Single-phase
    14. Create: Peculiarities #3397790
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    15. Create: The volume of the built-in boiler #3397791
      Value: 60 l
    16. Create: Expansion tank volume #3397792
      Value: 12 l
    17. Create: Equipment #3397793
      Value: Built-in boiler, display
    18. Create: Fuel #3397794
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3397795
      Value: 3.7 cu. m/hour
    20. Create: LPG consumption #3397796
      Value: 2.76 kg/hour
    21. Create: Nominal pressure of natural gas #3397797
      Value: 20 mbar
    22. Create: Permissible LPG pressure #3397798
      Value: 29 mbar
    23. Create: Heat carrier temperature #3397799
      Value: 40 - 90 °С
    24. Create: Temperature in the DHW circuit #3397800
      Value: 65 - 50 °C
    25. Create: Hot water capacity at t 30°C #3397801
      Value: 24.2 l/min
    26. Create: Max. water pressure in the DHW circuit #3397802
      Value: 6 bar
    27. Create: Max. water pressure in the heating circuit #3397803
      Value: 3 bar
    28. Create: Gas connection #3397804
      Value: 1/2"
    29. Create: Heating circuit connection #3397805
      Value: 1"
    30. Create: Branch pipe for connecting the DHW circuit #3397806
      Value: 3/4"
    31. Create: Chimney diameter #3397807
      Value: 150 mm
    32. Create: Dimensions WxHxD #3397808
      Value: 600x1370x800mm
    33. Create: Weight #3397809
      Value: 180.5 kg
    34. Create: Image #6321258
      URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
    35. Create: Image #6321259
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id8450076250138870632/orig
    36. Create: Preview image #6321260
      URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
  2. Donny Darko 30 April 2023 08:23:08
    Name: Gas Fondital Bali BTNE 32 31.4 kW double-circuit; Catalog: Heating boilers