Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:34:06
Create:
Description #3397743
Value: Type of heating boiler: gas, max. thermal power: 31.40 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3397744
Value: Gas, convection
Create:
Burner #3397745
Value: Gas
Create:
Number of circuits #3397746
Value: Double-circuit
Create:
Max. thermal power #3397747
Value: 31.40 kW
Create:
Max. thermal load #3397748
Value: 34.80 kW
Create:
The combustion chamber #3397749
Value: Open
Create:
Efficiency #3397750
Value: 90.22 %
Create:
Control #3397751
Value: Electronic
Create:
Installation #3397752
Value: Floor
Create:
Primary heat exchanger material #3397753
Value: Cast iron
Create:
Secondary heat exchanger material #3397754
Value: Stainless steel
Create:
Mains voltage #3397755
Value: Single-phase
Create:
Peculiarities #3397756
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3397757
Value: 60 l
Create:
Expansion tank volume #3397758
Value: 12 l
Create:
Equipment #3397759
Value: Built-in boiler, display
Create:
Fuel #3397760
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3397761
Value: 3.7 cu. m/hour
Create:
LPG consumption #3397762
Value: 2.76 kg/hour
Create:
Nominal pressure of natural gas #3397763
Value: 20 mbar
Create:
Permissible LPG pressure #3397764
Value: 29 mbar
Create:
Heat carrier temperature #3397765
Value: 40 - 90 °С
Create:
Temperature in the DHW circuit #3397766
Value: 65 - 50 °C
Create:
Hot water capacity at t 30°C #3397767
Value: 24.2 l/min
Create:
Max. water pressure in the DHW circuit #3397768
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3397769
Value: 3 bar
Create:
Gas connection #3397770
Value: 1/2"
Create:
Heating circuit connection #3397771
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3397772
Value: 3/4"
Create:
Chimney diameter #3397773
Value: 150 mm
Create:
Dimensions WxHxD #3397774
Value: 600x1370x800mm
Create:
Weight #3397775
Value: 194.5 kg
Create:
Additional Information #3397776
Value: Expansion tank of the DHW circuit with a volume of 5 liters; DHW circuit pump
Create:
Image #6321255
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
Create:
Image #6321256
URL: https://avatars.mds.yandex.net/get-mpic/1605421/img_id815014263497112502/orig
Create:
Preview image #6321257
URL: https://avatars.mds.yandex.net/get-mpic/1865219/img_id1208481040415610931/orig
Donny Darko 30 April 2023 08:23:08
Name: Gas Fondital Bali BTNE 32 V 31.4 kW double-circuit; Catalog: Heating boilers