Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:33:57
Create:
Description #3397673
Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3397674
Value: Gas, convection
Create:
Burner #3397675
Value: Gas
Create:
Number of circuits #3397676
Value: Double-circuit
Create:
Max. thermal power #3397677
Value: 32 kW
Create:
Max. thermal load #3397678
Value: 34.40 kW
Create:
The combustion chamber #3397679
Value: Closed
Create:
Efficiency #3397680
Value: 93.1 %
Create:
Control #3397681
Value: Electronic
Create:
Installation #3397682
Value: Floor
Create:
Primary heat exchanger material #3397683
Value: Cast iron
Create:
Secondary heat exchanger material #3397684
Value: Stainless steel
Create:
Mains voltage #3397685
Value: Single-phase
Create:
Peculiarities #3397686
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3397687
Value: 60 l
Create:
Expansion tank volume #3397688
Value: 12 l
Create:
Equipment #3397689
Value: Built-in boiler, display
Create:
Fuel #3397690
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3397691
Value: 3.64 cu. m/hour
Create:
LPG consumption #3397692
Value: 2.7 kg/hour
Create:
Nominal pressure of natural gas #3397693
Value: 20 mbar
Create:
Permissible LPG pressure #3397694
Value: 29 mbar
Create:
Heat carrier temperature #3397695
Value: 40 - 90 °С
Create:
Temperature in the DHW circuit #3397696
Value: 50 - 65 °С
Create:
Hot water capacity at t 30°C #3397697
Value: 24.5 l/min
Create:
Max. water pressure in the DHW circuit #3397698
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3397699
Value: 3 bar
Create:
Gas connection #3397700
Value: 1/2"
Create:
Heating circuit connection #3397701
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3397702
Value: 3/4"
Create:
Coaxial chimney diameter #3397703
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3397704
Value: Yes
Create:
Dimensions WxHxD #3397705
Value: 600x1370x800mm
Create:
Weight #3397706
Value: 239 kg
Create:
Additional Information #3397707
Value: Expansion tank of the DHW circuit with a volume of 5 liters; DHW circuit pump
Create:
Image #6321249
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id276048654913446974/orig
Create:
Image #6321250
URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id6861464563972942695/orig
Create:
Preview image #6321251
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id276048654913446974/orig
Donny Darko 30 April 2023 08:23:07
Name: Gas Fondital Bali BTSFE 32 V 32 kW double-circuit; Catalog: Heating boilers