Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 05:33:54
Create:
Description #3397638
Value: Type of heating boiler: gas, max. heating power: 36.50 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3397639
Value: Gas, convection
Create:
Burner #3397640
Value: Gas
Create:
Number of circuits #3397641
Value: Double-circuit
Create:
Max. thermal power #3397642
Value: 36.50 kW
Create:
Max. thermal load #3397643
Value: 39.20 kW
Create:
The combustion chamber #3397644
Value: Closed
Create:
Efficiency #3397645
Value: 93.1 %
Create:
Control #3397646
Value: Electronic
Create:
Installation #3397647
Value: Floor
Create:
Primary heat exchanger material #3397648
Value: Cast iron
Create:
Secondary heat exchanger material #3397649
Value: Stainless steel
Create:
Mains voltage #3397650
Value: Single-phase
Create:
Peculiarities #3397651
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3397652
Value: 60 l
Create:
Expansion tank volume #3397653
Value: 12 l
Create:
Equipment #3397654
Value: Built-in boiler, display
Create:
Fuel #3397655
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3397656
Value: 4.15 cu. m/hour
Create:
LPG consumption #3397657
Value: 3.1 kg/hour
Create:
Nominal pressure of natural gas #3397658
Value: 20 mbar
Create:
Permissible LPG pressure #3397659
Value: 29 mbar
Create:
Heat carrier temperature #3397660
Value: 40 - 90 °С
Create:
Temperature in the DHW circuit #3397661
Value: 50 - 65 °С
Create:
Hot water capacity at t 30°C #3397662
Value: 25.3 l/min
Create:
Max. water pressure in the DHW circuit #3397663
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3397664
Value: 3 bar
Create:
Gas connection #3397665
Value: 1/2"
Create:
Heating circuit connection #3397666
Value: 1"
Create:
Branch pipe for connecting the DHW circuit #3397667
Value: 3/4"
Create:
Coaxial chimney diameter #3397668
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3397669
Value: Yes
Create:
Dimensions WxHxD #3397670
Value: 600x1370x800mm
Create:
Weight #3397671
Value: 225.5 kg
Create:
Additional Information #3397672
Value: Expansion tank of the DHW circuit with a volume of 5 liters; DHW circuit pump
Create:
Image #6321246
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id276048654913446974/orig
Create:
Image #6321247
URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id2150891352482395783/orig
Create:
Preview image #6321248
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id276048654913446974/orig
Donny Darko 30 April 2023 08:23:07
Name: Gas Fondital Bali BTSFE 36 36.5 kW double-circuit; Catalog: Heating boilers